.. zephyr:code-sample:: sgp40_sht4x
:name: SGP40 and SHT4X digital humidity and multipixel gas sensor
:relevant-api: sensor_interface
Get temperature, humidity and gas sensor data from SGP40 and SHT4X sensors (polling mode).
Description
***********
This sample application periodically measures the ambient temperature, humidity
and a raw gas sensor value from an SGP40 and SHT4X device.
The result is written to the console.
You can choose to use the on-chip T/RH compensation of the SGP40
by feeding the values measured by the SHT4X into it.
This is enabled in the Application by default, you can turn it off
by setting ``APP_USE_COMPENSATION=n``.
The SHT4X has the option to use a heater which makes sense for specific
environments/applications (refer to the datasheet for more information).
To make use of the heater have a look at the Kconfig options for this application.
References
**********
- `SHT4X sensor <https://www.sensirion.com/en/environmental-sensors/humidity-sensors/humidity-sensor-sht4x/>`_
- `SGP40 sensor <https://www.sensirion.com/en/environmental-sensors/gas-sensors/sgp40/>`_
Wiring
******
This sample uses the SHT4X and SGP40 sensor controlled using the I2C interface.
Connect Supply: **VDD**, **GND** and Interface: **SDA**, **SCL**.
The supply voltage can be in the 1.7V to 3.6V range.
Depending on the baseboard used, the **SDA** and **SCL** lines require Pull-Up
resistors.
Building and Running
********************
This project outputs sensor data to the console. It requires a SHT4X and a SGP40
sensor. It should work with any platform featuring a I2C peripheral
interface. This example has an example device tree overlay
for the :ref:`blackpill_f411ce` board.
.. zephyr-app-commands::
:zephyr-app: samples/sensor/sgp40_sht4x
:board: blackpill_f411ce
:goals: build flash
Sample Output
=============
.. code-block:: console
*** Booting Zephyr OS build v2.6.0-rc1-315-g50d8d1187138 ***
SHT4X: 23.64 Temp. [C] ; 30.74 RH [%] -- SGP40: 30531 Gas [a.u.]
[00:00:00.250,000] <dbg> SGP40.sgp40_init: SGP40: Selftest succeeded!
SHT4X: 23.66 Temp. [C] ; 32.16 RH [%] -- SGP40: 30541 Gas [a.u.]
SHT4X: 23.63 Temp. [C] ; 30.83 RH [%] -- SGP40: 30522 Gas [a.u.]
The datasheet states that the raw sensor signal for the SGP40 ist proportional
to the logarithm of the sensors resistance, hence it is labeled as [a.u.]
(arbitrary units) in the example.