zephyr/samples/sensor/sht3xd
Gerard Marull-Paretas 93b63df762 samples, tests: convert string-based twister lists to YAML lists
Twister now supports using YAML lists for all fields that were written
as space-separated lists. Used twister_to_list.py script. Some artifacts
on string length are due to how ruamel dumps content.

Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
2023-05-10 09:52:37 +02:00
..
boards
src
CMakeLists.txt
README.rst
prj.conf
sample.yaml
trigger.conf

README.rst

.. _sht3xd:

SHT3XD: High accuracy digital I2C humidity sensor
#################################################

Description
***********

This sample application periodically (2 Hz) measures the ambient
temperature and humidity. The result is written to the console.
Optionally, it also shows how to use the upper threshold triggers.

References
**********

 - `SHT3X-DIS sensor <https://www.sensirion.com/en/environmental-sensors/humidity-sensors/digital-humidity-sensors-for-various-applications/>`_

Wiring
*******

This sample uses the SHT3X_DIS sensor controlled using the I2C interface.
Connect Supply: **VDD**, **GND** and Interface: **SDA**, **SCL**
and optionally connect the **ALERT** to a interrupt capable GPIO.
The supply voltage can be in the 2.15V to 5.5V range.
Depending on the baseboard used, the **SDA** and **SCL** lines require Pull-Up
resistors.

Building and Running
********************

This project outputs sensor data to the console. It requires a SHT3XD
sensor. It should work with any platform featuring a I2C peripheral
interface.  It does not work on QEMU.  In this example below the
:ref:`nrf51_ble400` board is used.


.. zephyr-app-commands::
   :zephyr-app: samples/sensor/sht3xd
   :board: nrf51_ble400
   :goals: build flash

Sample Output
=============

.. code-block:: console

   SHT3XD: 19.64 Cel ; 41.96 %RH
   SHT3XD: 19.74 Cel ; 42.06 %RH
   SHT3XD: 19.75 Cel ; 42.08 %RH

<repeats endlessly>