zephyr/tests/drivers/can/timing/Kconfig

41 lines
1.1 KiB
Plaintext

# Copyright (c) 2024 Vestas Wind Systems A/S
# SPDX-License-Identifier: Apache-2.0
mainmenu "CAN timing test"
config TEST_ALL_BITRATES
bool "Test all CAN in Automation (CiA) recommended bitrates"
help
Enable test of all bitrates recommended by CAN in Automation (CiA). Not all CAN
controllers can meet all of the bitrates listed below, and some board configurations may
impose limits on which bitrates can be met due to limitations in the CAN core clock
frequency selection.
CiA 301 lists the following nominal bitrates as recommended:
- 10 kbit/s
- 20 kbit/s
- 50 kbit/s
- 125 kbit/s
- 250 kbit/s
- 500 kbit/s
- 800 kbit/s
- 1 Mbit/s
CiA 601-2 lists the following exemplary CAN FD data phase bitrates:
- 1.0 Mbit/s
- 2.0 Mbit/s
- 4.0 Mbit/s
- 5.0 Mbit/s
- 8.0 Mbit/s
CiA 601-3 recommends the following CAN FD core clock frequencies for good node
interoperability. The higher the frequency, the better:
- 20 MHz
- 40 MHz
- 80 MHz
If this option is not enabled, the tests will be limited to a historical, safe set of CAN
bitrates.
source "Kconfig.zephyr"