# Copyright (c) 2020 PHYTEC Messtechnik GmbH
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
|
|
menuconfig IEEE802154_DW1000
|
|
bool "Decawave DW1000 Driver support"
|
|
depends on NETWORKING && SPI
|
|
|
|
if IEEE802154_DW1000
|
|
|
|
config IEEE802154_DW1000_SNIFF_ONT
|
|
int "SNIFF on time"
|
|
default 0
|
|
range 0 15
|
|
help
|
|
SNIFF on time in unit of PAC. The minimum on time is the duration
|
|
of two PACs. The SNIFF counter always adds 1 PAC unit to the on-time
|
|
count. The SNIFF_ONT value should be in range of 1-15.
|
|
Zero value disables SNIFF mode.
|
|
|
|
config IEEE802154_DW1000_SNIFF_OFFT
|
|
int "SNIFF off time"
|
|
default 16
|
|
range 1 255
|
|
help
|
|
SNIFF off time in unit of approximate 1 microsecond.
|
|
|
|
config IEEE802154_DW1000_INIT_PRIO
|
|
int "DW1000 initialization priority"
|
|
default 80
|
|
help
|
|
Set the initialization priority number. Do not mess with it unless
|
|
you know what you are doing. Beware DW1000 requires gpio and spi to
|
|
be ready first (and sometime gpio should be the very first as spi
|
|
might need it too). And of course it has to start before the net stack.
|
|
|
|
endif
|