83 lines
2.2 KiB
YAML
83 lines
2.2 KiB
YAML
#
|
|
# Copyright 2021 The Chromium OS Authors
|
|
# Copyright 2021 Grinn
|
|
#
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
#
|
|
|
|
description: |
|
|
TI INA230 and INA231 Bidirectional Current and Power Monitor.
|
|
The <zephyr/dt-bindings/sensor/ina230.h> file should be included in the
|
|
DeviceTree and it provides macro that can be used for initializing the
|
|
configuration register.
|
|
|
|
compatible: "ti,ina230"
|
|
|
|
include: ti,ina23x-common.yaml
|
|
|
|
properties:
|
|
config:
|
|
type: int
|
|
deprecated: true
|
|
default: 0x0000
|
|
description: |
|
|
Value of the configuration register
|
|
e.g shunt voltage and bus voltage ADC conversion
|
|
times, ADC and averaging, and ADC operating mode.
|
|
|
|
alert-config:
|
|
type: int
|
|
description: Diag alert register, default matches the power-on reset value
|
|
|
|
adc-mode:
|
|
type: string
|
|
description: |
|
|
ADC channel conversion configuration.
|
|
Default is the power-on reset value.
|
|
default: "Bus and shunt voltage continuous"
|
|
enum:
|
|
- "Shutdown single shot"
|
|
- "Shunt Voltage single shot"
|
|
- "Bus Voltage single shot"
|
|
- "Bus and Shunt Voltage single shot"
|
|
- "Shutdown continuous"
|
|
- "Shunt voltage continuous"
|
|
- "Bus voltage continuous"
|
|
- "Bus and shunt voltage continuous"
|
|
|
|
vbus-conversion-time-us:
|
|
type: int
|
|
description: |
|
|
Vbus conversion time in microseconds.
|
|
Default is the power-on reset value.
|
|
default: 1100
|
|
enum: [140, 204, 332, 588, 1100, 2116, 4156, 8244]
|
|
|
|
vshunt-conversion-time-us:
|
|
type: int
|
|
description: |
|
|
Vshunt conversion time in microseconds.
|
|
Default is the power-on reset value.
|
|
default: 1100
|
|
enum: [140, 204, 332, 588, 1100, 2116, 4156, 8244]
|
|
|
|
avg-count:
|
|
type: int
|
|
description: |
|
|
Number of samples to average (applies to all inputs).
|
|
Default is the power-on reset value.
|
|
default: 1
|
|
enum: [1, 4, 16, 64, 128, 256, 512, 1024]
|
|
|
|
mask:
|
|
type: int
|
|
default: 0
|
|
# default all alert sources to disabled
|
|
description: Mask register, default matches the power-on reset value
|
|
|
|
alert-limit:
|
|
type: int
|
|
default: 0
|
|
# default alert limit is 0V
|
|
description: Alert register, default matches the power-on reset value
|