description: Texas Instruments Bidirectional Current/Power Sensor
|
|
|
|
compatible: "ti,ina219"
|
|
|
|
include: [sensor-device.yaml, i2c-device.yaml]
|
|
|
|
properties:
|
|
lsb-microamp:
|
|
type: int
|
|
required: true
|
|
description: |
|
|
Current LSB in microAmpere
|
|
Current LSB = max expected current [A] / 2^15
|
|
example: 100 -> ~3A
|
|
shunt-milliohm:
|
|
type: int
|
|
required: true
|
|
description: |
|
|
Value of the shunt resistor in milliOhm
|
|
brng:
|
|
type: int
|
|
default: 1
|
|
description: |
|
|
Bus Voltage Range
|
|
0 = 16 V FSR
|
|
1 = 32 V FSR
|
|
|
|
The default of 32V is the power-on reset value of the device.
|
|
|
|
Should the expected bus voltage be below 16V set this to 0.
|
|
enum:
|
|
- 0
|
|
- 1
|
|
pg:
|
|
type: int
|
|
default: 3
|
|
description: |
|
|
Programmable Gain
|
|
0 = 1 -> ±40 mV
|
|
1 = /2 -> ±80 mV
|
|
2 = /4 -> ±160 mV
|
|
3 = /8 -> ±320 mV
|
|
|
|
The default of ±320 mV is the power-on reset value of the device.
|
|
|
|
In case the expected voltage drop across the shunt resistor is lower
|
|
one can adjust this to get more accurate readings.
|
|
enum:
|
|
- 0
|
|
- 1
|
|
- 2
|
|
- 3
|
|
badc:
|
|
type: int
|
|
default: 3
|
|
description: |
|
|
Bus ADC configuration
|
|
0 = 9 bit -> 84 µs
|
|
1 = 10 bit -> 148 µs
|
|
2 = 11 bit -> 276 µs
|
|
3 = 12 bit -> 532 µs
|
|
9 = 12 bit - 2 sample averaging -> 1.06 ms
|
|
10 = 12 bit - 4 sample averaging -> 2.13 ms
|
|
11 = 12 bit - 8 sample averaging -> 4.26 ms
|
|
12 = 12 bit - 16 sample averaging -> 8.51 ms
|
|
13 = 12 bit - 32 sample averaging -> 17.02 ms
|
|
14 = 12 bit - 64 sample averaging -> 34.05 ms
|
|
15 = 12 bit - 128 sample averaging -> 68.10 ms
|
|
|
|
The default of 12 bit is the power-on reset value of the device.
|
|
|
|
Lowering the resolution of the ADC gives less accurate readings but
|
|
cuts down on conversion times.
|
|
|
|
Averaging over multiple samples gives more stable readings but adds
|
|
to overall conversion time.
|
|
enum:
|
|
- 0
|
|
- 1
|
|
- 2
|
|
- 3
|
|
- 9
|
|
- 10
|
|
- 11
|
|
- 12
|
|
- 13
|
|
- 14
|
|
- 15
|
|
sadc:
|
|
type: int
|
|
default: 3
|
|
description: |
|
|
Shunt ADC configuration
|
|
0 = 9 bit -> 84 µs
|
|
1 = 10 bit -> 148 µs
|
|
2 = 11 bit -> 276 µs
|
|
3 = 12 bit -> 532 µs
|
|
9 = 12 bit - 2 sample averaging -> 1.06 ms
|
|
10 = 12 bit - 4 sample averaging -> 2.13 ms
|
|
11 = 12 bit - 8 sample averaging -> 4.26 ms
|
|
12 = 12 bit - 16 sample averaging -> 8.51 ms
|
|
13 = 12 bit - 32 sample averaging -> 17.02 ms
|
|
14 = 12 bit - 64 sample averaging -> 34.05 ms
|
|
15 = 12 bit - 128 sample averaging -> 68.10 ms
|
|
|
|
The default of 12 bit is the power-on reset value of the device.
|
|
|
|
Lowering the resolution of the ADC gives less accurate readings but
|
|
cuts down on conversion times.
|
|
|
|
Averaging over multiple samples gives more stable readings but adds
|
|
to overall conversion time.
|
|
enum:
|
|
- 0
|
|
- 1
|
|
- 2
|
|
- 3
|
|
- 9
|
|
- 10
|
|
- 11
|
|
- 12
|
|
- 13
|
|
- 14
|
|
- 15
|