zephyr/dts/bindings/display/sitronix,st7789v.yaml

116 lines
2.4 KiB
YAML

# Copyright (c) 2019, Marc Reilly <marc@cpdesign.com.au>
# Copyright (c) 2019, PHYTEC Messtechnik GmbH
# SPDX-License-Identifier: Apache-2.0
description: ST7789V 320x240 display controller
compatible: "sitronix,st7789v"
include: [spi-device.yaml, display-controller.yaml]
properties:
reset-gpios:
type: phandle-array
required: false
description: |
RESET pin.
The RESET pin of ST7789V is active low.
If connected directly the MCU pin should be configured
as active low.
cmd-data-gpios:
type: phandle-array
required: true
description: |
D/CX pin.
The D/CX pin of ST7789V is active low (transmission command byte).
If connected directly the MCU pin should be configured
as active low.
x-offset:
type: int
required: true
description: The column offset in pixels of the LCD to the controller memory
y-offset:
type: int
required: true
description: The row offset in pixels of the LCD to the controller memory
vcom:
type: int
required: true
description: VCOM Setting
gctrl:
type: int
required: true
description: Gate Control
vrhs:
type: int
required: false
description: VRH Setting
vdvs:
type: int
required: false
description: VDV Setting
mdac:
type: int
required: true
description: Memory Data Access Control
lcm:
type: int
required: true
description: LCM Setting
colmod:
type: int
required: true
description: Interface Pixel Format
gamma:
type: int
required: true
description: Gamma Setting
porch-param:
type: uint8-array
required: true
description: Porch Setting
cmd2en-param:
type: uint8-array
required: true
description: Command 2 Enable Parameter
pwctrl1-param:
type: uint8-array
required: true
description: Power Control 1 Parameter
pvgam-param:
type: uint8-array
required: true
description: Positive Voltage Gamma Control Parameter
nvgam-param:
type: uint8-array
required: true
description: Negative Voltage Gamma Control Parameter
ram-param:
type: uint8-array
required: true
description: RAM Control Parameter
rgb-param:
type: uint8-array
required: true
description: RGB Interface Control Parameter