# LM77 temperature sensor configuration
|
|
#
|
|
# Copyright (c) 2021 Vestas Wind Systems A/S
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
|
|
menuconfig LM77
|
|
bool "LM77 Temperature Sensor"
|
|
default $(dt_compat_enabled,lm77)
|
|
depends on I2C
|
|
help
|
|
Enable driver for the LM77 digital temperature sensor with 2-wire
|
|
interface.
|
|
|
|
config LM77_TRIGGER
|
|
bool "Trigger support"
|
|
depends on LM77
|
|
default y
|
|
help
|
|
Enable trigger support for the LM77 digital temperature sensor.
|
|
|
|
Trigger events are based on the LM77 INT signal (configured for event
|
|
interrupt mode). After a trigger event the LM77 temperature must be
|
|
read in order to reset and rearm the trigger.
|
|
|
|
if LM77_TRIGGER
|
|
|
|
config LM77_TRIGGER_THREAD_STACK_SIZE
|
|
int "Stack size for the trigger workqueue thread"
|
|
default 512
|
|
help
|
|
Size of the stack used for the internal trigger workqueue thread.
|
|
|
|
config LM77_TRIGGER_THREAD_PRIO
|
|
int "Priority for the trigger workqueue thread"
|
|
default 0
|
|
help
|
|
Priority level for the internal trigger workqueue thread.
|
|
|
|
endif # LM77_TRIGGER
|