According to the UART API documentation, implementation must block when
the transceiver is full. For CDC ACM UART, TX ringbuffer can be
considered as transceiver buffer/FIFO. Blocking when the USB subsystem
is not ready is considered highly undesirable behavior. Blocking may
also be undesirable when CDC ACM UART is used as a logging backend.
Change the behavior of CDC ACM poll out to:
- Block if the TX ring buffer is full, hw_flow_control property is
enabled, and called from a non-ISR context.
- Do not block if the USB subsystem is not ready, poll out
implementation is called from an ISR context, or hw_flow_control
property is disabled.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>