zephyr/samples/sensor/sgp40_sht4x/Kconfig

45 lines
971 B
Plaintext

#
# Copyright (c) 2021 Leonard Pollak
#
# SPDX-License-Identifier: Apache-2.0
#
mainmenu "SGP40/SHT4X sample application"
config APP_USE_COMPENSATION
bool "Use the T/RH compensation feature of the SGP40"
default y
config APP_USE_HEATER
bool "Use the Heater on the SHT4X"
default n
help
Maximum duty cycle for using the heater is 5%
config APP_HEATER_HUMIDITY_THRESH
int "RH [%] threshold above which the heater will be activated"
range 0 99
default 65
depends on APP_USE_HEATER
config APP_HEATER_PULSE_POWER
int "Heater Power Setting"
range 0 2
default 2
depends on APP_USE_HEATER
help
0 -> High power heater pulse -> ~200 mW @3.3V
1 -> Medium power heater pulse -> ~110 mW @3.3V
2 -> Low power heater pulse -> ~20 mW @3.3V
config APP_HEATER_PULSE_DURATION
int "Heater Pulse Length Setting"
range 0 1
default 1
depends on APP_USE_HEATER
help
0 -> Long heater pulse -> 1.1s
1 -> Short heater pulse -> 0.11s
source "Kconfig.zephyr"