zephyr/samples/sensor/ens210
Kumar Gala 5d36157c7c sensors: Remove unnecessary Kconfig setting of sensors
Sensor Kconfig sybmols should be enabled if CONFIG_SENSOR=y
and the devicetree node for the sensor is enabled.  We can
remove explicitly enabling specific sensor drivers in .conf
files.

Signed-off-by: Kumar Gala <galak@kernel.org>
2022-07-25 15:18:56 +02:00
..
src
CMakeLists.txt
README.rst
ens210.overlay samples: sensors: Remove label property from devicetree overlays 2022-07-19 08:23:35 -05:00
prj.conf sensors: Remove unnecessary Kconfig setting of sensors 2022-07-25 15:18:56 +02:00
sample.yaml

README.rst

.. _ens210:

ams ens210 Relative Humidity and Temperature Sensor
###################################################

Overview
********

This sample application demonstrates how to use the ams ens210 sensor to
measure the ambient temperature and relative humidity.

Building and Running
********************

This sample application uses the sensor connected to the i2c stated in the
ens210.overlay file.
Flash the binary to a board of choice with a sensor connected.
For example build for a nucleo_f446re board:

.. zephyr-app-commands::
   :zephyr-app: samples/sensor/ens210
   :board: nucleo_f446re
   :goals: build flash
   :compact:

Sample Output
=============

.. code-block:: console

    device is 0x20001174, name is ENS210
    Temperature: 28.28881222 C; Humidity: 25.25689737%
    Temperature: 28.28912472 C; Humidity: 25.25799105%
    Temperature: 28.28959347 C; Humidity: 25.25760045%