# SPDX-License-Identifier: Apache-2.0
description: |
Nordic nPM1300 PMIC
The PMIC has two buck converters and two LDOs.
The regulators need to be defined as child nodes, strictly following the
BUCK1,2 LDO1..2, node names. For
example:
pmic@6b {
reg = <0x6b>;
...
regulators {
compatible = "nordic,npm1300-regulator";
BUCK1 {
/* all properties for BUCK1 */
};
BUCK2 {
/* all properties for BUCK2 */
};
LDO1 {
/* all properties for LDO1 */
};
LDO2 {
/* all properties for LDO2 */
};
};
};
compatible: "nordic,npm1300-regulator"
include: base.yaml
properties:
dvs-gpios:
type: phandle-array
description: |
List of SOC GPIOs connected to PMIC GPIOs.
Set_dvs_mode will drive these pins as follows:
DVS mode 1 will enable the first pin
DVS mode 2 will enable the second pin
DVS mode 3 will drive the first and second pins
etc.
The effect of the mode change is defined by the enable-gpios
and pwm_gpios fields for each of the regulator blocks.
child-binding:
include:
- name: regulator.yaml
property-allowlist:
- regulator-always-on
- regulator-boot-on
- regulator-boot-off
- regulator-min-microvolt
- regulator-max-microvolt
- regulator-init-microvolt
- regulator-allowed-modes
- regulator-initial-mode
- regulator-min-microamp
- regulator-max-microamp
- startup-delay-us
- off-on-delay-us
properties:
retention-microvolt:
type: int
description: |
Retention mode voltage in microvolts.
enable-gpios:
type: phandle-array
description: |
Regulator enable controlled by specified regulator GPIO pin.
When set regulator must be enabled/disabled using set_dvs_mode.
pwm-gpios:
type: phandle-array
description: |
Regulator enable controlled by specified regulator GPIO pin.
When set regulator must be enabled/disabled using set_dvs_mode.
retention-gpios:
type: phandle-array
description: |
Retention mode controlled by specified regulator GPIO pin.
soft-start-microamp:
type: int
enum:
- 10000
- 20000
- 35000
- 50000
description: |
Soft start current limit in microamps.