.. _modbus-rtu-server-sample:
|
|
|
|
Modbus RTU Server Sample
|
|
########################
|
|
|
|
Overview
|
|
********
|
|
|
|
This is a simple application demonstrating a Modbus RTU server implementation
|
|
in Zephyr RTOS.
|
|
|
|
Requirements
|
|
************
|
|
|
|
This sample has been tested with the nRF52840-DK and FRDM-K64F boards,
|
|
but it should work with any board that has a free UART interface or USB
|
|
device controller. Additionally the board should have three LEDs.
|
|
|
|
RTU server example is running on an evaluation board. Client is running
|
|
on a PC or laptop.
|
|
|
|
The description of this sample uses `PyModbus`_ (Pymodbus REPL).
|
|
The user can of course try out other client implementations with this sample.
|
|
|
|
Using RS-485 transceiver
|
|
========================
|
|
|
|
It is the default configuration of this sample.
|
|
In addition to the evaluation board, an USB to RS-485 bus adapter and
|
|
a RS-485 shield are required. The shield converts UART TX, RX signals to RS-485.
|
|
An Arduino header compatible shield like `joy-it RS-485 shield for Arduino`_
|
|
can be used. This example uses DE signal, which is controlled by pin D9
|
|
on the JOY-IT shield. For other shields, ``de-gpios`` property must be adapted
|
|
or removed in the application overlay file
|
|
:zephyr_file:`samples/subsys/modbus/rtu_server/app.overlay`
|
|
|
|
The USB to RS-485 adapter connects to the USB port of a computer.
|
|
The two A+, B- lines should be connected to the RS-485 shield.
|
|
|
|
Using CDC ACM UART
|
|
==================
|
|
|
|
Only an evaluation board with supported USB device controller is required.
|
|
USB device port should be connected to the USB port of a computer.
|
|
Although it is only a point to point connection and does not represent a bus,
|
|
it can, apart from testing the server implementation, also be used practically
|
|
for example to control relays or to read ADC values via USB connection without
|
|
implementing custom USB class or driver.
|
|
|
|
Building and Running
|
|
********************
|
|
|
|
This sample can be found under
|
|
:zephyr_file:`samples/subsys/modbus/rtu_server` in the Zephyr tree.
|
|
|
|
The following commands build and flash RTU server sample.
|
|
|
|
.. zephyr-app-commands::
|
|
:zephyr-app: samples/subsys/modbus/rtu_server
|
|
:board: nrf52840dk_nrf52840
|
|
:goals: build flash
|
|
:compact:
|
|
|
|
The following commands build and flash RTU server sample using CDC ACM UART.
|
|
|
|
.. zephyr-app-commands::
|
|
:zephyr-app: samples/subsys/modbus/rtu_server
|
|
:board: nrf52840dk_nrf52840
|
|
:goals: build flash
|
|
:gen-args: -DDTC_OVERLAY_FILE=cdc-acm.overlay -DOVERLAY_CONFIG=overlay-cdc-acm.conf
|
|
:compact:
|
|
|
|
On the client side, PC or laptop, the following command connects PyModbus
|
|
to the RTU server. If CDC ACM UART is used, ttyUSB should be replaced by a
|
|
matching ttyACM device.
|
|
|
|
.. code-block:: console
|
|
|
|
# pymodbus.console serial --port /dev/ttyUSB0 --baudrate 19200
|
|
--bytesize 8 --parity N --stopbits 2
|
|
|
|
The LEDs on the board are controlled by Modbus commands FC01, FC05, FC15.
|
|
For example, to set LED0 on use FC01 command (write_coil).
|
|
|
|
.. code-block:: console
|
|
|
|
> client.write_coil address=0 value=1 unit=1
|
|
|
|
Client should confirm successful communication and LED0 should light.
|
|
|
|
.. code-block:: console
|
|
|
|
{
|
|
"address": 0,
|
|
"value": true
|
|
}
|
|
|
|
To set LED0 off but LED1 and LED2 on use FC15 command (write_coils).
|
|
|
|
.. code-block:: console
|
|
|
|
> client.write_coils address=0 values=0,1,1 unit=1
|
|
|
|
To read LED0, LED1, LED2 state FC05 command (read_coils) can be used.
|
|
|
|
.. code-block:: console
|
|
|
|
> client.read_coils address=0 count=3 unit=1
|
|
{
|
|
"bits": [
|
|
false,
|
|
true,
|
|
true,
|
|
false,
|
|
false,
|
|
false,
|
|
false,
|
|
false
|
|
]
|
|
}
|
|
|
|
It is also possible to write and read the holding registers.
|
|
This however does not involve any special interaction
|
|
with the peripherals on the board yet.
|
|
|
|
To write single holding registers use FC06 command (write_register),
|
|
|
|
.. code-block:: console
|
|
|
|
> client.write_register address=0 value=42 unit=1
|
|
|
|
or FC16 command (write_registers).
|
|
|
|
.. code-block:: console
|
|
|
|
> client.write_registers address=0 values=42,42,42 unit=1
|
|
|
|
To read holding registers use FC03 command (read_holding_registers).
|
|
|
|
.. code-block:: console
|
|
|
|
> client.read_holding_registers address=0 count=3 unit=1
|
|
{
|
|
"registers": [
|
|
42,
|
|
42,
|
|
42
|
|
]
|
|
}
|
|
|
|