zephyr/samples/sensor/sht3xd
Anas Nashif 8c1f89fa99 cleanup: include/: move sensor.h to drivers/sensor.h
move sensor.h to drivers/sensor.h and
create a shim for backward-compatibility.

No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.

Related to #16539

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
2019-06-27 22:55:49 -04:00
..
src
CMakeLists.txt
README.rst
efr32mg_sltb004a.overlay
frdm_k64f.overlay
nrf51_ble400.overlay
nrf52840_pca10056.overlay
nucleo_l476rg.overlay
prj.conf
sample.yaml
trigger.conf

README.rst

.. _sht3xd:

SHT3XD: High accuracy digital I2C humidity sensor
#################################################

Description
***********

This sample application periodically (2 Hz) measures the ambient
temperature and humidity. The result is written to the console.
Optionally, it also shows how to use the upper threshold triggers.

References
**********

 - `SHT3X-DIS sensor <https://www.sensirion.com/en/environmental-sensors/humidity-sensors/digital-humidity-sensors-for-various-applications/>`_

Wiring
*******

This sample uses the SHT3X_DIS sensor controlled using the I2C interface.
Connect Supply: **VDD**, **GND** and Interface: **SDA**, **SCL**
and optionally connect the **ALERT** to a interrupt capable GPIO.
The supply voltage can be in the 2.15V to 5.5V range.
Depending on the baseboard used, the **SDA** and **SCL** lines require Pull-Up
resistors.

Building and Running
********************

This project outputs sensor data to the console. It requires a SHT3XD
sensor. It should work with any platform featuring a I2C peripheral
interface.  It does not work on QEMU.  In this example below the
:ref:`nrf51_ble400` board is used.


.. zephyr-app-commands::
   :zephyr-app: samples/sensors/sht3xd
   :board: nrf51_ble400
   :goals: build flash

Sample Output
=============

.. code-block:: console

   SHT3XD: 19.64 Cel ; 41.96 %RH
   SHT3XD: 19.74 Cel ; 42.06 %RH
   SHT3XD: 19.75 Cel ; 42.08 %RH

<repeats endlessly>