92 lines
2.3 KiB
ReStructuredText
92 lines
2.3 KiB
ReStructuredText
.. _lps22hh_i3c:
|
|
|
|
LPS22HH: Temperature and Pressure Monitor (I3C)
|
|
###############################################
|
|
|
|
Overview
|
|
********
|
|
This sample periodically reads pressure from the LPS22HH MEMS pressure
|
|
sensor and displays it on the console.
|
|
|
|
Requirements
|
|
************
|
|
|
|
This sample uses the LPS22HH sensor controlled using the I3C interface.
|
|
It has been tested using the LPS22HH on the evaluation board
|
|
STEVALMKI192-V1 connected to the I3C header on :ref:`mimxrt685_evk`.
|
|
|
|
References
|
|
**********
|
|
|
|
- LPS22HH: https://www.st.com/en/mems-and-sensors/lps22hh.html
|
|
|
|
Building and Running
|
|
********************
|
|
|
|
This project outputs sensor data to the console. It requires an LPS22HH
|
|
sensor (for example, the one on evaluation board STEVALMKI192-V1).
|
|
|
|
.. note::
|
|
|
|
If ``CONFIG_LPS22HH_TRIGGER`` is enabled, the trigger is using
|
|
I3C In-Band Interrupt (IBI) to signal new data being available.
|
|
Since IBI is initiated by the sensor, it will take over the I3C
|
|
bus. Therefore, when flashing a new image, a power cycle is needed
|
|
to reset the sensor so that it will not generate IBIs anymore.
|
|
Or else the I3C controller will not be able to be initialized,
|
|
resulting in the sample not being able to communicate with
|
|
the sensor.
|
|
|
|
Building on mimxrt685_evk board
|
|
====================================
|
|
|
|
.. zephyr-app-commands::
|
|
:zephyr-app: samples/sensor/lps22hh_i3c
|
|
:host-os: unix
|
|
:board: mimxrt685_evk/mimxrt685s/cm33
|
|
:goals: build
|
|
:compact:
|
|
|
|
Board Preparations
|
|
==================
|
|
|
|
mimxrt685_evk
|
|
------------------
|
|
|
|
On the board :ref:`mimxrt685_evk`, the I3C pins are exposed on the J18
|
|
header, where:
|
|
|
|
* SCL is on pin 1
|
|
* SDA is on pin 2
|
|
* Internal pull-up is on pin 3 (which is connected to pin 2 already)
|
|
* Ground is on pin4
|
|
|
|
LPS22HH
|
|
^^^^^^^
|
|
|
|
A LPS22HH sensor needs to be connected to this header. For example,
|
|
the evaluation board STEVAL-MKI192V1 can be used. This needs to be
|
|
prepared so that the LPS22HH sensor has address 0x5D (i.e. 0xBA,
|
|
left-shifed).
|
|
|
|
Sample Output
|
|
=============
|
|
|
|
.. code-block:: console
|
|
|
|
Configured for triggered collection at 1 Hz
|
|
Observation: 1
|
|
Pressure: 97.474 kPa
|
|
Temperature: 22.19 C
|
|
Observation: 2
|
|
Pressure: 97.466 kPa
|
|
Temperature: 22.21 C
|
|
Observation: 3
|
|
Pressure: 97.473 kPa
|
|
Temperature: 22.21 C
|
|
Observation: 4
|
|
Pressure: 97.455 kPa
|
|
Temperature: 22.21 C
|
|
|
|
<repeats endlessly every second>
|