zephyr/samples/sensor/th02
Anas Nashif 470c5f3189 tests: remove testcase.ini files
We now use yaml files.

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
2017-06-21 20:56:53 -04:00
..
src license: Replace Apache boilerplate with SPDX tag 2017-01-19 03:50:58 +00:00
Makefile samples: tests: remove obsolete KERNEL_TYPE and kernel variables 2016-11-04 15:47:25 -04:00
README.rst doc: fix board/sample broken links 2017-06-13 20:49:13 -04:00
prj.conf sensors: th02: convert to and build with unified kernel 2016-11-03 01:45:50 +00:00
sample.yaml tests: samples: convert testcase files to yaml 2017-06-21 20:56:53 -04:00

README.rst

.. _th02-sample:

TH02: Temperature and Humidity Monitor
######################################

Overview
********
This sample periodically reads temperature and humidity from the Grove
Temperature & Humidity Sensor (TH02) and display the results on the Grove LCD
display.


Requirements
************

This sample uses the TH02 sensor and the grove LCD display. Both devices are
controlled using the I2C interface.

More details about the sensor and the display can be found here:

- `Grove Temperature And Humidity`_
- `Grove LCD Module`_

Wiring
******

The easiest way to get this wired is to use the Grove shield and connect both
devices to I2C. No additional wiring is required. Depending on the board you are
using you might need to connect two 10K ohm resistors to SDL and and SDA (I2C).
The LCD display requires 5 volts, so the voltage switch on the shield needs to
be on 5v.


References
**********

 - TH02: http://www.datasheetspdf.com/mobile/748107/TH02.html


.. _Grove LCD Module: http://wiki.seeed.cc/Grove-LCD_RGB_Backlight/
.. _Grove Temperature And Humidity: http://wiki.seeed.cc/Grove-TemptureAndHumidity_Sensor-High-Accuracy_AndMini-v1.0/