# Kconfig - AMG88XX infrared thermopile sensor configuration options
|
|
|
|
#
|
|
# Copyright (c) 2017 Phytec Messtechnik GmbH
|
|
#
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
#
|
|
|
|
menuconfig AMG88XX
|
|
bool "AMG88XX Infrared Thermopile Sensor"
|
|
depends on I2C
|
|
help
|
|
Enable driver for AMG88XX infrared thermopile sensor.
|
|
|
|
if AMG88XX
|
|
|
|
config AMG88XX_NAME
|
|
string "Driver name"
|
|
default "AMG88XX"
|
|
help
|
|
Device name identifying the AMG88XX sensor.
|
|
|
|
config AMG88XX_I2C_ADDR
|
|
hex "I2C address for AMG88XX Sensor"
|
|
default "0x68"
|
|
range 0x68 0x69
|
|
help
|
|
I2C address of the AMG88XX sensor.
|
|
|
|
0x68: AD-SELECT connected GND
|
|
0x69: AD-SELECT connected VDD
|
|
|
|
config AMG88XX_I2C_MASTER_DEV_NAME
|
|
string "I2C master where AMG88XX is connected"
|
|
default "I2C_0"
|
|
help
|
|
The I2C master device's name where the AMG88XX sensor is connected.
|
|
|
|
choice
|
|
prompt "Trigger mode"
|
|
default AMG88XX_TRIGGER_NONE
|
|
help
|
|
Specify the type of triggering used by the driver.
|
|
|
|
config AMG88XX_TRIGGER_NONE
|
|
bool "No trigger"
|
|
|
|
config AMG88XX_TRIGGER_GLOBAL_THREAD
|
|
bool "Use global thread"
|
|
depends on GPIO
|
|
select AMG88XX_TRIGGER
|
|
|
|
config AMG88XX_TRIGGER_OWN_THREAD
|
|
bool "Use own thread"
|
|
depends on GPIO
|
|
select AMG88XX_TRIGGER
|
|
|
|
endchoice
|
|
|
|
config AMG88XX_TRIGGER
|
|
bool
|
|
|
|
config AMG88XX_GPIO_DEV_NAME
|
|
string "GPIO device"
|
|
default "GPIO_0"
|
|
depends on AMG88XX_TRIGGER
|
|
help
|
|
The GPIO device's name where the AMG88XX interrupt (alert) pin is
|
|
connected.
|
|
|
|
config AMG88XX_GPIO_PIN_NUM
|
|
int "Interrupt GPIO pin number"
|
|
default 0
|
|
depends on AMG88XX_TRIGGER
|
|
help
|
|
The GPIO pin number receiving the interrupt signal from the
|
|
AMG88XX sensor.
|
|
|
|
config AMG88XX_THREAD_PRIORITY
|
|
int "Thread priority"
|
|
depends on AMG88XX_TRIGGER_OWN_THREAD
|
|
default 10
|
|
help
|
|
Priority of thread used by the driver to handle interrupts.
|
|
|
|
config AMG88XX_THREAD_STACK_SIZE
|
|
int "Thread stack size"
|
|
depends on AMG88XX_TRIGGER_OWN_THREAD
|
|
default 1024
|
|
help
|
|
Stack size of thread used by the driver to handle interrupts.
|
|
|
|
endif #if AMG88XX
|