# Kconfig.bmp280 - BMP280 temperature and pressure sensor configuration options
|
|
|
|
#
|
|
# Copyright (c) 2016 Intel Corporation
|
|
# Copyright (c) 2017 IpTronix S.r.l.
|
|
#
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
#
|
|
menuconfig BME280
|
|
bool "BME280/BMP280 sensor"
|
|
depends on I2C || SPI
|
|
default n
|
|
help
|
|
Enable driver for BME280 I2C-based or SPI-based temperature and pressure sensor.
|
|
|
|
config BME280_DEV_NAME
|
|
string "BME280 device name"
|
|
depends on BME280
|
|
default "BME280"
|
|
|
|
choice
|
|
prompt "BME280 device select"
|
|
depends on BME280
|
|
default BME280_DEV_TYPE_I2C
|
|
help
|
|
Select interface to communicate with BME280 sensor. This sensor can communicate
|
|
with both SPI and I2C. I2C is the default, select SPI if you sensor is connected
|
|
via the SPI interface.
|
|
|
|
config BME280_DEV_TYPE_SPI
|
|
depends on SPI
|
|
bool "SPI"
|
|
config BME280_DEV_TYPE_I2C
|
|
depends on I2C
|
|
bool "I2C"
|
|
endchoice
|
|
|
|
config BME280_I2C_ADDR
|
|
hex "BME280 I2C slave address"
|
|
default 0x76
|
|
depends on BME280 && BME280_DEV_TYPE_I2C
|
|
help
|
|
Specify the I2C slave address for the BME280.
|
|
|
|
0x76: Ground
|
|
0x77: VCC
|
|
|
|
config BME280_I2C_MASTER_DEV_NAME
|
|
string "I2C master where BME280 is connected"
|
|
depends on BME280 && BME280_DEV_TYPE_I2C
|
|
default "I2C_0"
|
|
help
|
|
Specify the device name of the I2C master device to which BME280 is
|
|
connected.
|
|
|
|
config BME280_SPI_DEV_NAME
|
|
string "SPI device where BME280 is connected"
|
|
depends on BME280 && BME280_DEV_TYPE_SPI
|
|
default "SPI_0"
|
|
help
|
|
Specify the device name of the SPI device to which BME280 is
|
|
connected.
|
|
|
|
config BME280_SPI_DEV_SLAVE
|
|
int "SPI Slave Select where BME280 is connected"
|
|
depends on BME280 && BME280_DEV_TYPE_SPI
|
|
default 3
|
|
help
|
|
Specify the Slave Select pin of the SPI device to which BME280 CS is
|
|
connected.
|
|
|
|
menu "Attributes"
|
|
depends on BME280
|
|
|
|
choice
|
|
prompt "BME280 temperature oversampling"
|
|
depends on BME280
|
|
default BME280_TEMP_OVER_2X
|
|
help
|
|
Select temperature oversampling for the BME280 sensor. Higher values
|
|
lead to more accurate readings, but higher power consumption.
|
|
config BME280_TEMP_OVER_1X
|
|
bool "x1"
|
|
config BME280_TEMP_OVER_2X
|
|
bool "x2"
|
|
config BME280_TEMP_OVER_4X
|
|
bool "x4"
|
|
config BME280_TEMP_OVER_8X
|
|
bool "x8"
|
|
config BME280_TEMP_OVER_16X
|
|
bool "x16"
|
|
endchoice
|
|
|
|
choice
|
|
prompt "BME280 pressure oversampling"
|
|
depends on BME280
|
|
default BME280_PRESS_OVER_16X
|
|
help
|
|
Select pressure oversampling for the BME280 sensor. Higher values
|
|
lead to more accurate readings, but higher power consumption.
|
|
config BME280_PRESS_OVER_1X
|
|
bool "x1"
|
|
config BME280_PRESS_OVER_2X
|
|
bool "x2"
|
|
config BME280_PRESS_OVER_4X
|
|
bool "x4"
|
|
config BME280_PRESS_OVER_8X
|
|
bool "x8"
|
|
config BME280_PRESS_OVER_16X
|
|
bool "x16"
|
|
endchoice
|
|
|
|
choice
|
|
prompt "BME280 humidity oversampling"
|
|
depends on BME280
|
|
default BME280_HUMIDITY_OVER_16X
|
|
help
|
|
Select humidity oversampling for the BME280 sensor. Higher values
|
|
lead to more accurate readings, but higher power consumption.
|
|
config BME280_HUMIDITY_OVER_1X
|
|
bool "x1"
|
|
config BME280_HUMIDITY_OVER_2X
|
|
bool "x2"
|
|
config BME280_HUMIDITY_OVER_4X
|
|
bool "x4"
|
|
config BME280_HUMIDITY_OVER_8X
|
|
bool "x8"
|
|
config BME280_HUMIDITY_OVER_16X
|
|
bool "x16"
|
|
endchoice
|
|
|
|
choice
|
|
prompt "BME280 standby time"
|
|
depends on BME280
|
|
default BME280_STANDBY_1000MS
|
|
help
|
|
Select standby time between measurements for the BME280 sensor.
|
|
Higher values lead to lower power consumption.
|
|
config BME280_STANDBY_05MS
|
|
bool "0.5ms"
|
|
config BME280_STANDBY_62MS
|
|
bool "62.5ms"
|
|
config BME280_STANDBY_125MS
|
|
bool "125ms"
|
|
config BME280_STANDBY_250MS
|
|
bool "250ms"
|
|
config BME280_STANDBY_500MS
|
|
bool "500ms"
|
|
config BME280_STANDBY_1000MS
|
|
bool "1000ms"
|
|
config BME280_STANDBY_2000MS
|
|
bool "2000ms BMP280 / 10ms BME280"
|
|
config BME280_STANDBY_4000MS
|
|
bool "4000ms BMP280 / 20ms BME280"
|
|
endchoice
|
|
|
|
choice
|
|
prompt "BME280 filter coefficient"
|
|
depends on BME280
|
|
default BME280_FILTER_4
|
|
help
|
|
Select the filter coefficient for the BME280 sensor.
|
|
config BME280_FILTER_OFF
|
|
bool "filter off"
|
|
config BME280_FILTER_2
|
|
bool "2"
|
|
config BME280_FILTER_4
|
|
bool "4"
|
|
config BME280_FILTER_8
|
|
bool "8"
|
|
config BME280_FILTER_16
|
|
bool "16"
|
|
endchoice
|
|
|
|