# Kconfig - Bosch BMG160 gyroscope configuration options # # Copyright (c) 2016 Intel Corporation # # SPDX-License-Identifier: Apache-2.0 # menuconfig BMG160 bool "Bosch BMG160 gyroscope support" depends on SENSOR depends on I2C default n help Enable Bosch BMG160 gyroscope support. config BMG160_DRV_NAME string "Driver's name" depends on BMG160 default "bmg160" help Name for the BMG160 driver which will be used for binding. config BMG160_I2C_PORT_NAME string "I2C master controller port name" depends on BMG160 default "I2C_0" help Master I2C port name through which BMG160 chip is accessed. config BMG160_I2C_ADDR hex "BMG160 I2C address" depends on BMG160 default 0x68 help BMG160 chip's I2C address. Chip supports two addresses: 0x68 and 0x69 (if SDO pin is pulled to GND). choice prompt "BMG160 I2C bus speed" default BMG160_I2C_SPEED_STANDARD depends on BMG160 config BMG160_I2C_SPEED_STANDARD bool "Standard" help Standard bus speed of up to 100kHz. config BMG160_I2C_SPEED_FAST bool "Fast" help Fast bus speed of up to 400KHz. endchoice choice prompt "Trigger mode" depends on BMG160 default BMG160_TRIGGER_GLOBAL_THREAD help Specify the type of triggering to be used by the driver. config BMG160_TRIGGER_NONE bool prompt "No trigger" config BMG160_TRIGGER_GLOBAL_THREAD bool "Use global thread" select BMG160_TRIGGER config BMG160_TRIGGER_OWN_THREAD bool "Use own thread" select BMG160_TRIGGER endchoice config BMG160_TRIGGER bool depends on BMG160 config BMG160_THREAD_PRIORITY int "Own thread priority" depends on BMG160 && BMG160_TRIGGER_OWN_THREAD default 10 help The priority of the thread used for handling interrupts. config BMG160_THREAD_STACK_SIZE int "Own thread stack size" depends on BMG160 && BMG160_TRIGGER_OWN_THREAD default 1024 help The thread stack size. config BMG160_GPIO_PORT_NAME string "GPIO controller port name" depends on BMG160 && BMG160_TRIGGER default "GPIO_0" help The gpio controller the interrupt pin is attached to. config BMG160_INT_PIN hex "BMG160 INT PIN" depends on BMG160 && BMG160_TRIGGER default 2 help BMG160 interrupt pin. choice prompt "Gyroscope range setting." depends on BMG160 default BMG160_RANGE_RUNTIME config BMG160_RANGE_RUNTIME bool "Set at runtime." config BMG160_RANGE_2000DPS bool "2000 DPS" config BMG160_RANGE_1000DPS bool "1000 DPS" config BMG160_RANGE_500DPS bool "500 DPS" config BMG160_RANGE_250DPS bool "250 DPS" config BMG160_RANGE_125DPS bool "125 DPS" endchoice choice prompt "Gyroscope sampling frequency." depends on BMG160 default BMG160_ODR_RUNTIME config BMG160_ODR_RUNTIME bool "Set at runtime." config BMG160_ODR_100 bool "100 Hz" config BMG160_ODR_200 bool "200 Hz" config BMG160_ODR_400 bool "400 Hz" config BMG160_ODR_1000 bool "1000 Hz" config BMG160_ODR_2000 bool "2000 Hz" endchoice