# # Copyright (c) 2021 Jimmy Johnson # # SPDX-License-Identifier: Apache-2.0 # mainmenu "TMP108 sample application" config APP_REPORT_TEMP_ALERTS bool "Report over and under temperature alerts" default n config APP_ENABLE_ONE_SHOT bool "Enable one shot low power mode" default n help One shot requires a callback to be invoked after the tmp108 has woken up and taken a temperature reading, calling sample_fetch starts this process. Set this to enable 1 shot mode example. config APP_TEMP_ALERT_HIGH_THRESH int "RH [%] high threshold for alert trigger in celcius" range 0 50 default 26 help Set this to enable alerts for high temperatures although this will work with one shot enabled, it requires continuous monitoring mode to be enabled to work in real time. See spec sheet for more details. config APP_TEMP_ALERT_LOW_THRESH int "RH [%] low threshold for alert trigger in celcius" range 0 50 default 18 help Set this to enable alerts for low temperatures although this will work with one shot enabled, it requires continuous monitoring mode to be enabled to work in real time. See spec sheet for more details. source "Kconfig.zephyr"