# Kconfig - TMP112 temperature sensor configuration options # # Copyright (c) 2016 Firmwave # # SPDX-License-Identifier: Apache-2.0 # menuconfig TMP112 bool prompt "TMP112 Temperature Sensor" depends on I2C default n help Enable the driver for Texas Instruments TMP112 High-Accuracy Digital Temperature Sensors. The TMP102 is compatible with the TMP112 but is less accurate and has been successfully tested with this driver. config TMP112_NAME string prompt "Driver name" default "TMP112" depends on TMP112 help Device name with which the TMP112 sensor is identified. config TMP112_I2C_ADDR hex "I2C address for TMP112" depends on TMP112 default 0x48 help I2C address of the TMP112 sensor. 0x48: A0 connected GND and A1 connected to GND. 0x49: A0 connected VDD and A1 connected to GND. 0x4A: A0 connected SDA and A1 connected to GND. 0x4B: A0 connected SCL and A1 connected to GND. config TMP112_I2C_MASTER_DEV_NAME string prompt "I2C master where TMP112 is connected" depends on TMP112 default "I2C_0" help Specify the device name of the I2C master device to which the TMP112 chip is connected.