# Copyright (c) 2020 PHYTEC Messtechnik GmbH # SPDX-License-Identifier: Apache-2.0 menuconfig IEEE802154_DW1000 bool "Decawave DW1000 Driver support" default y depends on DT_HAS_DECAWAVE_DW1000_ENABLED select SPI if IEEE802154_DW1000 config IEEE802154_DW1000_SNIFF_ONT int "SNIFF on time" default 0 range 0 15 help SNIFF on time in unit of PAC. The minimum on time is the duration of two PACs. The SNIFF counter always adds 1 PAC unit to the on-time count. The SNIFF_ONT value should be in range of 1-15. Zero value disables SNIFF mode. config IEEE802154_DW1000_SNIFF_OFFT int "SNIFF off time" default 16 range 1 255 help SNIFF off time in unit of approximate 1 microsecond. config IEEE802154_DW1000_INIT_PRIO int "DW1000 initialization priority" default 80 help Set the initialization priority number. Do not mess with it unless you know what you are doing. Beware DW1000 requires gpio and spi to be ready first (and sometime gpio should be the very first as spi might need it too). And of course it has to start before the net stack. endif