# Micropower, 3-Axis, +/-200g Digital Accelerometer # Copyright (c) 2023 Analog Devices Inc. # SPDX-License-Identifier: Apache-2.0 menuconfig ADXL367 bool "ADXL367 Three Axis High-g I2C/SPI accelerometer" default y depends on DT_HAS_ADI_ADXL367_ENABLED select I2C if $(dt_compat_on_bus,$(DT_COMPAT_ADI_ADXL367),i2c) select SPI if $(dt_compat_on_bus,$(DT_COMPAT_ADI_ADXL367),spi) help Enable driver for ADXL367 Three-Axis Digital Accelerometers. if ADXL367 choice ADXL367_OP_MODE prompt "Operating mode" default ADXL367_MEASUREMENT_MODE config ADXL367_MEASUREMENT_MODE bool "Measurement Mode" help In this mode, acceleration data is provided continuously at the output data rate (ODR). endchoice config ADXL367_ACTIVITY_THRESHOLD int "Activity threshold in raw value" range 0 8191 default 100 help Threshold for activity detection. config ADXL367_INACTIVITY_THRESHOLD int "In-activity threshold in raw value" range 0 8191 default 100 help Threshold for in-activity detection. config ADXL367_ACTIVITY_TIME int "Activity time" range 0 $(UINT8_MAX) default 100 help The activity timer implements a robust activity detection that minimizes false positive motion triggers. When the timer is used, only sustained motion can trigger activity detection. Value is the number of samples. For example, at 100Hz ODR, 100 value translates to 1 second. config ADXL367_INACTIVITY_TIME int "In-activity time" range 0 $(UINT16_MAX) default 100 help The time that all enabled axes must be lower than the inactivity threshold for an inactivity event to be detected. Value is the number of samples. For example, at 100Hz ODR, 100 value translates to 1 second. config ADXL367_ACTIVITY_DETECTION_MODE bool "Use activity detection" default y help Enable Activity detection. config ADXL367_INACTIVITY_DETECTION_MODE bool "Use inactivity detection" default y help Enable Inactivity detection. config ADXL367_REFERENCED_ACTIVITY_DETECTION_MODE bool "Use referenced activity detection" default y help Activity detection can be configured as referenced or absolute. When using absolute activity detection, acceleration samples are compared directly to a user set threshold to determine whether motion is present. config ADXL367_REFERENCED_INACTIVITY_DETECTION_MODE bool "Use referenced inactivity detection" default y help Inactivity detection can be configured as referenced or absolute. When using absolute inactivity detection, acceleration samples are compared directly to a user set threshold to determine whether motion is present. choice ADXL367_TRIGGER_MODE prompt "Trigger mode" default ADXL367_TRIGGER_NONE help Specify the type of triggering used by the driver. config ADXL367_TRIGGER_NONE bool "No trigger" config ADXL367_TRIGGER_GLOBAL_THREAD bool "Use global thread" depends on GPIO select ADXL367_TRIGGER config ADXL367_TRIGGER_OWN_THREAD bool "Use own thread" depends on GPIO select ADXL367_TRIGGER endchoice config ADXL367_TRIGGER bool config ADXL367_THREAD_PRIORITY int "Thread priority" depends on ADXL367_TRIGGER_OWN_THREAD && ADXL367_TRIGGER default 10 help Priority of thread used by the driver to handle interrupts. config ADXL367_THREAD_STACK_SIZE int "Thread stack size" depends on ADXL367_TRIGGER_OWN_THREAD && ADXL367_TRIGGER default 1024 help Stack size of thread used by the driver to handle interrupts. endif # ADXL367