This emulates a RISC-V in 64-bit mode on a SiFive FE310 dev board.
Memory is tight so a few tests had to be disabled due to the extra
memory usage compared to qemu_riscv32.
Signed-off-by: Nicolas Pitre <npitre@baylibre.com>
Update the files which contain no license information with the
'Apache-2.0' SPDX license identifier. Many source files in the tree are
missing licensing information, which makes it harder for compliance
tools to determine the correct license.
By default all files without license information are under the default
license of Zephyr, which is Apache version 2.
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
Nios2 platform was disabled due to compilation error. Meanwhile,
issue has been solved and tests can be re-enabled.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Changed 'in place' mode to bypass logger system and directly
call active backends. With this approach memory footprint of
the logger can be significantly reduced in terms of RAM and ROM.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Move to latest cmake version with many bug fixes and enhancements.
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Extended logger configuration to allow function name prefix for
messages with certain severity levels. By default only debug
messages are prefixed with function name.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Shell log backends were initialized from shell context. After
lowering logger thread priority order has been flipped. That
revealed a bug where shell logger backend was enabled before
backend ID's has been assigned during logger initialization.
ID assignment is moved to log backend enabling function making
it independent of order of initialization.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Extended logger suite to test correctness of reporting dropped
log messages.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Changed LOG_MODULE_REGISTER and LOG_MODULE_DECLARE macros to take log
level as optional parameter. LOG_MODULE_DECLARE can now also be used
in static inline functions in headers. Added LOG_LEVEL_SET macro
which is used when instance logging API is used to indicate maximal
log level compiled into the file.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
When using an IDE (e.g. Eclipse, Qt Creator), the project name gets
displayed. This greatly simplifies the navigation between projects when
having many of them open at the same time. Naming every project "NONE"
defeats this functionality.
This patch tries to use sensible project names while not duplicating
too much of what is already represented in the path. This is done by
using the name of the directory the relevant CMakeLists.txt file is
stored in. To ensure unique project names in the samples (and again, in
the tests folder) folder, small manual adjustments have been done.
Signed-off-by: Reto Schneider <code@reto-schneider.ch>
Extended logger to support optional log message prepending with
function name.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Extended supported number of arguments in log message. Support for
messages consisting of more than 2 chunks had to be added. So far
messages could consist of one chunk (up to 3 args) or two chunks
(2 args in first chunk and 7 in second chunk). Once 2+ chunks
support is added number of arguments is techinically limited to
15 (4 bit field). log_core and log_output extended to suppor 10
arguments.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Log_core test was failing due to test structure elements not being
correctly reset before the test.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Extended macro to accept flag indicating if given backend must be
initialized and enabled when log subsystem starts. Typically, simple
backends will have autostart flag set. More complex may require
explicit enabling (e.g. shell over BLE can only be enabled when
BLE connection is established).
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Extending logger to support logging transient strings (with %s).
With dedicated call (log_strdup), string is duplicated to a buffer
from internal logger pool. Logger implicitly manages the pool.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
tests/subsys/logging/log_core does not work if inplace processing
is set and the process thread is disabled.
So let's set the valid configuration in its project file
Signed-off-by: Alberto Escolar Piedras <alpi@oticon.com>
Rather than having some implied name for the logging name, explicitly
pass it in the macros LOG_MODULE_REGISTER & LOG_MODULE_DECLARE.
Signed-off-by: Kumar Gala <kumar.gala@linaro.org>
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Rather than having some implied name for the logging name, explicitly
pass it in the macros LOG_MODULE_REGISTER & LOG_MODULE_DECLARE.
Signed-off-by: Kumar Gala <kumar.gala@linaro.org>
Prepend the text 'cmake_minimum_required(VERSION 3.8.2)' into the
application and test build scripts.
Modern versions of CMake will spam users with a deprecation warning
when the toplevel CMakeLists.txt does not specify a CMake
version. This is documented in bug #8355.
To resolve this we include a cmake_minimum_required() line into the
toplevel build scripts. Additionally, cmake_minimum_required is
invoked from within boilerplate.cmake. The highest version will be
enforced.
This patch allows us to afterwards change CMake policy CMP000 from OLD
to NEW which in turn finally rids us of the verbose warning.
The extra boilerplate is considered more acceptable than the verbosity
of the CMP0000 policy.
Signed-off-by: Sebastian Bøe <sebastian.boe@nordicsemi.no>
Log API can be used before user can explicitly initialize the logger.
In order to ensure that logger core is ready to buffer log messages
it must be initialize as early as possible. Initialization does not
include initialization of default backend since driver may not be
ready and backend is needed only when log messages are processed.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>