Specify the units of the current LSB in microamperes, so that we can
measure low maximum currents. Right now it was specified in
milliamperes, but ignored and always hardcoded to 1mA in the driver.
This makes the driver pretty much useless when the maximum current to be
measured is in a range of e.g. 20-50mA.
This patch also removes some unnecessary ifdeffery: since we write the
calibration register, we can always provice measurements with the right
units. It is also wrong to provide sensor readings that do not match
with the units specified by the channel. After this change voltage is
always reported in V, current in A and power in W.
Note that power measurement had the current LSB hardcoded in the
calculation (assuming 1mA/LSB), this has been fixed as well.
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
- Add many missing includes so that headers are self-contained
- Sort includes properly (locals first, stdc, zephyr, etc.)
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
In order to bring consistency in-tree, migrate all drivers to the new
prefix <zephyr/...>. Note that the conversion has been scripted, refer
to #45388 for more details.
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
Create an explicit ina230 driver which is supposed to
work with 230 and 231 variants. While at it switch
to i2c_dt_spec helpers and change device-tree node
names to use - instead of _ in order to follow
convention.
Signed-off-by: Bartosz Bilas <b.bilas@grinn-global.com>