2018-11-25 02:09:36 +08:00
|
|
|
.. _ccs811:
|
|
|
|
|
|
|
|
CCS811 Indoor Air Quality Sensor
|
|
|
|
################################
|
|
|
|
|
|
|
|
Overview
|
|
|
|
********
|
|
|
|
|
|
|
|
The CCS811 digital gas sensor detects volatile organic compounds (VOCs)
|
|
|
|
for indoor air quality measurements. VOCs are often categorized as
|
|
|
|
pollutants and/or sensory irritants and can come from a variety of
|
|
|
|
sources such as construction materials (paint and carpet), machines
|
|
|
|
(copiers and processors), and even people (breathing and smoking). It
|
|
|
|
estimates carbon dioxide (CO2) levels where the main source of VOCs is
|
|
|
|
human presence.
|
|
|
|
|
|
|
|
Building and Running
|
|
|
|
********************
|
|
|
|
|
2020-04-03 02:32:14 +08:00
|
|
|
Building and Running on thingy52_nrf52832
|
|
|
|
=========================================
|
2018-11-25 02:09:36 +08:00
|
|
|
|
|
|
|
.. zephyr-app-commands::
|
|
|
|
:zephyr-app: samples/sensor/ccs811
|
2020-04-03 02:32:14 +08:00
|
|
|
:board: thingy52_nrf52832
|
2018-11-25 02:09:36 +08:00
|
|
|
:goals: build flash
|
|
|
|
:compact:
|
|
|
|
|
|
|
|
|
|
|
|
Sample Output
|
|
|
|
=============
|
|
|
|
|
|
|
|
The sample output below is from a `Nordic Thingy:52
|
|
|
|
<https://www.nordicsemi.com/Software-and-tools/Prototyping-platforms/Nordic-Thingy-52>`_
|
2020-04-03 02:32:14 +08:00
|
|
|
(thingy52_nrf52832) that includes this sensor (and others).
|
2018-11-25 02:09:36 +08:00
|
|
|
After a soft reset, there is a 5-second startup period
|
|
|
|
where readings are unstable, and then we can see steady
|
|
|
|
reported measurements of about 400 ppm eC02 and 0 ppb eTVOC.
|
|
|
|
|
|
|
|
.. code-block::console
|
|
|
|
|
|
|
|
*** Booting Zephyr OS build zephyr-v2.1.0-310-g32a3e9907bab ***
|
|
|
|
device is 0x20001088, name is CCS811
|
|
|
|
HW 12; FW Boot 1000 App 1100 ; mode 10
|
|
|
|
|
|
|
|
[0:00:00.046]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC
|
|
|
|
Voltage: 0.000000V; Current: 0.000000A
|
|
|
|
BASELINE fff4
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:01.059]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC
|
|
|
|
Voltage: 0.000000V; Current: 0.000000A
|
|
|
|
BASELINE fff4
|
|
|
|
Timed fetch got 0
|
|
|
|
Timed fetch got stale data
|
|
|
|
Timed fetch got stale data
|
|
|
|
Timed fetch got stale data
|
|
|
|
|
|
|
|
[0:00:05.084]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.677040V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:06.096]: CCS811: 405 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.675428V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:07.108]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.677040V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:08.121]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.677040V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:09.133]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.677040V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|
|
|
|
|
|
|
|
[0:00:10.145]: CCS811: 400 ppm eCO2; 0 ppb eTVOC
|
|
|
|
Voltage: 0.677040V; Current: 0.000014A
|
|
|
|
BASELINE 8384
|
|
|
|
Timed fetch got 0
|