@page TIM_PWMInput TIM PWM Input example
@verbatim
******************** (C) COPYRIGHT 2017 STMicroelectronics *******************
* @file TIM/TIM_PWMInput/readme.txt
* @author MCD Application Team
* @brief Description of the TIM PWM_Input example.
******************************************************************************
* @attention
*
* Copyright (c) 2017 STMicroelectronics.
* All rights reserved.
*
* This software is licensed under terms that can be found in the LICENSE file
* in the root directory of this software component.
* If no LICENSE file comes with this software, it is provided AS-IS.
*
******************************************************************************
@endverbatim
@par Example Description
This example shows how to use the TIM peripheral to measure the frequency and
duty cycle of an external signal.
The TIM3CLK frequency is set to SystemCoreClock (Hz), the Prescaler is 0 so the
counter clock is SystemCoreClock (Hz).
SystemCoreClock is set to 100 MHz for STM32F413xx/STM32F423xx Devices.
TIM3 is configured in PWM Input Mode: the external signal is connected to
TIM3 Channel2 used as input pin.
To measure the frequency and the duty cycle, we use the TIM3 CC2 interrupt request,
so in the TIM3_CC_IRQHandler routine, the frequency and the duty cycle of the external
signal are computed.
"uwFrequency" variable contains the external signal frequency:
TIM3 counter clock = SystemCoreClock,
uwFrequency = TIM3 counter clock / TIM3_CCR2 in Hz,
"uwDutyCycle" variable contains the external signal duty cycle:
uwDutyCycle = (TIM3_CCR1*100)/(TIM3_CCR2) in %.
The minimum frequency value to measure is (TIM3 counter clock / CCR MAX)
= (100 MHz)/ 65535
@note Care must be taken when using HAL_Delay(), this function provides accurate delay (in milliseconds)
based on variable incremented in SysTick ISR. This implies that if HAL_Delay() is called from
a peripheral ISR process, then the SysTick interrupt must have higher priority (numerically lower)
than the peripheral interrupt. Otherwise the caller ISR process will be blocked.
To change the SysTick interrupt priority you have to use HAL_NVIC_SetPriority() function.
@note The application need to ensure that the SysTick time base is always set to 1 millisecond
to have correct HAL operation.
@par Keywords
Timers, Input, signals, PWM, External signal, Frequency, Duty cycle, Measure
@par Directory contents
- TIM/TIM_PWMInput/Inc/stm32f4xx_hal_conf.h HAL configuration file
- TIM/TIM_PWMInput/Inc/stm32f4xx_it.h Interrupt handlers header file
- TIM/TIM_PWMInput/Inc/main.h Header for main.c module
- TIM/TIM_PWMInput/Src/stm32f4xx_it.c Interrupt handlers
- TIM/TIM_PWMInput/Src/main.c Main program
- TIM/TIM_PWMInput/Src/stm32f4xx_hal_msp.c HAL MSP file
- TIM/TIM_PWMInput/Src/system_stm32f4xx.c STM32F4xx system source file
@par Hardware and Software environment
- This example runs on STM32F413xx/STM32F423xx devices.
- This example has been tested with STMicroelectronics STM32F413ZH-Nucleo
board and can be easily tailored to any other supported device
and development board.
- STM32F413ZH-Nucleo Set-up
- Connect the external signal to measure to the TIM3 CH2 pin (PB.05) (connect to pin 13 in CN7 connector).
@par How to use it ?
In order to make the program work, you must do the following :
- Open your preferred toolchain
- Rebuild all files and load your image into target memory
- Run the example
*/