sof/tune/eq
Seppo Ingalsuo fa0735572b EQ Tool: Add calibration data import
This patch adds capability to apply for capture microphone calibration
data (ASCII text lines with Hz, dB values). The calibration data file
name needs to be edited into configuration file mls_rec_config.txt. Such
calibration data is provided by several inexpensive USB measurement
microphones manufacturers.

Signed-off-by: Seppo Ingalsuo <seppo.ingalsuo@linux.intel.com>
2018-10-29 11:51:00 +02:00
..
eq_align.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_alsactl_write.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_blob_write.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_coef_quant.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_compute.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_compute_response.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_compute_tot_response.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_defaults.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_define_parametric_eq.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_fir_blob_merge.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_fir_blob_pack.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_fir_blob_quant.m EQ FIR: Add check and removal for trailing zeros in filter coefficients 2018-09-19 16:36:22 +03:00
eq_iir_blob_merge.m SOFT: Add equalizer tuning scripts and small examples 2018-08-07 19:05:38 +03:00
eq_iir_blob_pack.m EQ: Fix an integer type bug in IIR coefficients blob packer 2018-10-15 10:54:48 +03:00
eq_iir_blob_quant.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_norm.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_plot.m EQ Tool: Fix compatibility with Matlab and improve accuracy of IIR filters 2018-08-30 13:49:17 +03:00
eq_tplg_write.m EQ tune: Update m4 format EQ filter coefficients syntax 2018-10-04 18:17:17 +03:00
example_fir_eq.m EQ Tool: Output topology m4 binary control style configuration data 2018-09-19 15:47:29 +03:00
example_iir_eq.m EQ Tool: Output topology m4 binary control style configuration data 2018-09-19 15:47:29 +03:00
example_spk_eq.m EQ Tool: Output topology m4 binary control style configuration data 2018-09-19 15:47:29 +03:00
mls_freq_resp.m EQ Tool: Add calibration data import 2018-10-29 11:51:00 +02:00
mls_play_config.txt EQ: Add tool for acoustical frequency response measurement 2018-10-10 16:43:38 +03:00
mls_rec_config.txt EQ Tool: Add calibration data import 2018-10-29 11:51:00 +02:00