signal/metag: Document a conflict with SI_USER with SIGFPE
Setting si_code to 0 results in a userspace seeing an si_code of 0.
This is the same si_code as SI_USER. Posix and common sense requires
that SI_USER not be a signal specific si_code. As such this use of 0
for the si_code is a pretty horribly broken ABI.
Further use of si_code == 0 guaranteed that copy_siginfo_to_user saw a
value of __SI_KILL and now sees a value of SIL_KILL with the result
hat uid and pid fields are copied and which might copying the si_addr
field by accident but certainly not by design. Making this a very
flakey implementation.
Utilizing FPE_FIXME siginfo_layout will now return SIL_FAULT and the
appropriate fields will reliably be copied.
Possible ABI fixes includee:
- Send the signal without siginfo
- Don't generate a signal
- Possibly assign and use an appropriate si_code
- Don't handle cases which can't happen
Cc: James Hogan <james.hogan@imgtec.com>
Cc: linux-metag@vger.kernel.org
Ref: ac919f0883
("metag: Traps")
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
This commit is contained in:
parent
b5daf2b9d1
commit
b80328be53
|
@ -6,4 +6,11 @@
|
|||
|
||||
#include <asm-generic/siginfo.h>
|
||||
|
||||
/*
|
||||
* SIGFPE si_codes
|
||||
*/
|
||||
#ifdef __KERNEL__
|
||||
#define FPE_FIXME 0 /* Broken dup of SI_USER */
|
||||
#endif /* __KERNEL__ */
|
||||
|
||||
#endif
|
||||
|
|
|
@ -735,7 +735,7 @@ TBIRES fpe_handler(TBIRES State, int SigNum, int Triggers, int Inst, PTBI pTBI)
|
|||
else if (error_state & TXSTAT_FPE_INEXACT_BIT)
|
||||
info.si_code = FPE_FLTRES;
|
||||
else
|
||||
info.si_code = 0;
|
||||
info.si_code = FPE_FIXME;
|
||||
info.si_errno = 0;
|
||||
info.si_addr = (__force void __user *)regs->ctx.CurrPC;
|
||||
force_sig_info(SIGFPE, &info, current);
|
||||
|
|