SUNRPC: Check if the xprt is connected before handling sysfs reads

xprts don't immediately reconnect when changing the "dstaddr" property,
instead this gets handled the next time an operation uses the transport.
This could lead to NULL pointer dereferences when trying to read sysfs
files between the disconnect and reconnect operations. Fix this by
returning an error if the xprt is not connected.

Signed-off-by: Anna Schumaker <Anna.Schumaker@Netapp.com>
Signed-off-by: Trond Myklebust <trond.myklebust@hammerspace.com>
This commit is contained in:
Anna Schumaker 2021-10-28 15:17:41 -04:00 committed by Trond Myklebust
parent 4330fe35b8
commit 17f09d3f61
1 changed files with 8 additions and 4 deletions

View File

@ -109,8 +109,10 @@ static ssize_t rpc_sysfs_xprt_srcaddr_show(struct kobject *kobj,
struct sock_xprt *sock;
ssize_t ret = -1;
if (!xprt)
return 0;
if (!xprt || !xprt_connected(xprt)) {
xprt_put(xprt);
return -ENOTCONN;
}
sock = container_of(xprt, struct sock_xprt, xprt);
if (kernel_getsockname(sock->sock, (struct sockaddr *)&saddr) < 0)
@ -129,8 +131,10 @@ static ssize_t rpc_sysfs_xprt_info_show(struct kobject *kobj,
struct rpc_xprt *xprt = rpc_sysfs_xprt_kobj_get_xprt(kobj);
ssize_t ret;
if (!xprt)
return 0;
if (!xprt || !xprt_connected(xprt)) {
xprt_put(xprt);
return -ENOTCONN;
}
ret = sprintf(buf, "last_used=%lu\ncur_cong=%lu\ncong_win=%lu\n"
"max_num_slots=%u\nmin_num_slots=%u\nnum_reqs=%u\n"