ASoC: cs35l41: Correct amp_gain_tlv values
The current analog gain TLV seems to have completely incorrect values in it. The gain starts at 0.5dB, proceeds in 1dB steps, and has no mute value, correct the control to match. Signed-off-by: Charles Keepax <ckeepax@opensource.cirrus.com> Link: https://lore.kernel.org/r/20230823085308.753572-1-ckeepax@opensource.cirrus.com Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
3b1f08833c
commit
1613781d7e
|
@ -168,7 +168,7 @@ static int cs35l41_get_fs_mon_config_index(int freq)
|
|||
static const DECLARE_TLV_DB_RANGE(dig_vol_tlv,
|
||||
0, 0, TLV_DB_SCALE_ITEM(TLV_DB_GAIN_MUTE, 0, 1),
|
||||
1, 913, TLV_DB_MINMAX_ITEM(-10200, 1200));
|
||||
static DECLARE_TLV_DB_SCALE(amp_gain_tlv, 0, 1, 1);
|
||||
static DECLARE_TLV_DB_SCALE(amp_gain_tlv, 50, 100, 0);
|
||||
|
||||
static const struct snd_kcontrol_new dre_ctrl =
|
||||
SOC_DAPM_SINGLE("Switch", CS35L41_PWR_CTRL3, 20, 1, 0);
|
||||
|
|
Loading…
Reference in New Issue