Power Management high-level design
|
|
##################################
|
|
|
|
P-state/C-state management
|
|
**************************
|
|
|
|
ACPI Px/Cx data
|
|
===============
|
|
|
|
CPU P-state/C-state are controlled by the guest OS. The ACPI
|
|
P/C-state driver relies on some P/C-state-related ACPI data in the guest
|
|
ACPI table.
|
|
|
|
SOS could run ACPI driver with no problem because it can access native
|
|
the ACPI table. For UOS though, we need to prepare the corresponding ACPI data
|
|
for Device Model to build virtual ACPI table.
|
|
|
|
The Px/Cx data includes four
|
|
ACPI objects: _PCT, _PPC, and _PSS for P-state management, and _CST for
|
|
C-state management. All these ACPI data must be consistent with the
|
|
native data because the control method is a kind of pass through.
|
|
|
|
These ACPI objects data are parsed by an offline tool and hard-coded in a
|
|
Hypervisor module named CPU state table:
|
|
|
|
.. code-block:: c
|
|
|
|
struct cpu_px_data {
|
|
uint64_t core_frequency; /* megahertz */
|
|
uint64_t power; /* milliWatts */
|
|
uint64_t transition_latency; /* microseconds */
|
|
uint64_t bus_master_latency; /* microseconds */
|
|
uint64_t control; /* control value */
|
|
uint64_t status; /* success indicator */
|
|
} __attribute__((aligned(8)));
|
|
|
|
struct acpi_generic_address {
|
|
uint8_t space_id;
|
|
uint8_t bit_width;
|
|
uint8_t bit_offset;
|
|
uint8_t access_size;
|
|
uint64_t address;
|
|
} __attribute__((aligned(8)));
|
|
|
|
struct cpu_cx_data {
|
|
struct acpi_generic_address cx_reg;
|
|
uint8_t type;
|
|
uint32_t latency;
|
|
uint64_t power;
|
|
} __attribute__((aligned(8)));
|
|
|
|
|
|
With these Px/Cx data, the Hypervisor is able to intercept guest's
|
|
P/C-state requests with desired restrictions.
|
|
|
|
Virtual ACPI table build flow
|
|
=============================
|
|
|
|
:numref:`vACPItable` shows how to build virtual ACPI table with
|
|
Px/Cx data for UOS P/C-state management:
|
|
|
|
.. figure:: images/hld-pm-image28.png
|
|
:align: center
|
|
:name: vACPItable
|
|
|
|
System block for building vACPI table with Px/Cx data
|
|
|
|
Some ioctl APIs are defined for Device model to query Px/Cx data from
|
|
SOS VHM. The Hypervisor needs to provide hypercall APIs to transit Px/Cx
|
|
data from CPU state table to SOS VHM.
|
|
|
|
The build flow is:
|
|
|
|
1) Use offline tool (e.g. **iasl**) to parse the Px/Cx data and hard-code to
|
|
CPU state table in Hypervisor. Hypervisor loads the data after
|
|
system boot up.
|
|
2) Before UOS launching, Device mode queries the Px/Cx data from SOS VHM
|
|
via ioctl interface.
|
|
3) VHM transmits the query request to Hypervisor by hypercall.
|
|
4) Hypervisor returns the Px/Cx data.
|
|
5) Device model builds the virtual ACPI table with these Px/Cx data
|
|
|
|
Intercept Policy
|
|
================
|
|
|
|
Hypervisor should be able to restrict guest's
|
|
P/C-state request, with a user-customized policy.
|
|
|
|
Hypervisor should intercept guest P-state request and validate whether
|
|
it is a valid P-state. Any invalid P-state (e.g. doesn't exist in CPU state
|
|
table) should be rejected.
|
|
|
|
It is better not to intercept C-state request because the trap would
|
|
impact both power and performance.
|
|
|
|
.. note:: For P-state control you should pay attention to SoC core
|
|
voltage domain design when doing P-state measurement. The highest
|
|
P-state would win if different P-state requests on the cores shared
|
|
same voltage domain. In this case APERF/MPERF must be used to see
|
|
what P-state was granted on that core.
|
|
|
|
S3/S5
|
|
*****
|
|
|
|
ACRN assumes guest has complete S3/S5 power state management and follows
|
|
the ACPI standard exactly. System S3/S5 needs to follow well-defined
|
|
enter/exit paths and cooperate among different components.
|
|
|
|
System low power state enter process
|
|
====================================
|
|
|
|
Each time, when OSPM of UOS starts power state transition, it will
|
|
finally write the ACPI register per ACPI spec requirement.
|
|
With help of ACRN I/O emulation framework, the UOS ACPI
|
|
register writing will be dispatched to Device Model and Device Model
|
|
will emulate the UOS power state (pause UOS VM for S3 and power off UOS
|
|
VM for S5)
|
|
|
|
The VM Manager monitors all UOS. If all active UOSes are in required power
|
|
state, VM Manager will notify OSPM of SOS to start SOS power state
|
|
transition. OSPM of SOS follows a very similar process as UOS for power
|
|
state transition. The difference is SOS ACPI register writing is trapped
|
|
to ACRN HV. And ACRN HV will emulate SOS power state (pause SOS VM for
|
|
S3 and no special action for S5)
|
|
|
|
Once SOS low power state is done, ACRN HV will go through its own low
|
|
power state enter path.
|
|
|
|
The whole system is finally put into low power state.
|
|
|
|
System low power state exit process
|
|
===================================
|
|
|
|
The low power state exit process is in reverse order. The ACRN
|
|
hypervisor is woken up at first. It will go through its own low power
|
|
state exit path. Then ACRN hypervisor will resume the SOS to let SOS go
|
|
through SOS low power state exit path. After that, the DM is resumed and
|
|
let UOS go through UOS low power state exit path. The system is resumed
|
|
to running state after at least one UOS is resumed to running state.
|
|
|
|
:numref:`pmworkflow` shows the flow of low power S3 enter/exit process (S5 follows
|
|
very similar process)
|
|
|
|
.. figure:: images/hld-pm-image62.png
|
|
:align: center
|
|
:name: pmworkflow
|
|
|
|
ACRN system power management workflow
|
|
|
|
For system power state entry:
|
|
|
|
1. UOS OSPM start UOS S3 entry
|
|
2. The UOS S3 entering request is trapped ACPI PM Device of DM
|
|
3. DM pauses UOS VM to emulate UOS S3 and notifies VM Manager that the UOS
|
|
dedicated to it is in S3
|
|
4. If all UOSes are in S3, VM Manager will notify OSPM of SOS
|
|
5. SOS OSPM starts SOS S3 enter
|
|
6. SOS S3 entering request is trapped to Sx Agency in ACRN HV
|
|
7. ACRN HV pauses SOS VM to emulate SOS S3 and starts ACRN HV S3 entry.
|
|
|
|
For system power state exit:
|
|
|
|
1. When system is resumed from S3, native bootloader will jump to wake
|
|
up vector of HV
|
|
2. HV resumes S3 and jumps to wake up vector to emulate SOS resume from S3
|
|
3. OSPM of SOS is running
|
|
4. OSPM of SOS notifies VM Manager that it's ready to wake up UOS
|
|
5. VM Manager will notify DM to resume the UOS
|
|
6. DM resets the UOS VM to emulate UOS resume from S3
|
|
|
|
According to ACPI standard, S3 is mapped to suspend to RAM and S5 is
|
|
mapped to shutdown. So the S5 process is a little different:
|
|
|
|
- UOS enters S3 -> UOS powers off
|
|
- System enters S3 -> System powers off
|
|
- System resumes From S3 -> System fresh start
|
|
- UOS resumes from S3 -> UOS fresh startup
|