The coding guideline rules C-TY-27 and C-TY-28, combined, requires that
assignment and arithmetic operations shall be applied only on operands of the
same kind. This patch either adds explicit type casts or adjust types of
variables to align the types of operands.
The only semantic change introduced by this patch is the promotion of the
second argument of set_vmcs_bit() and clear_vmcs_bit() to
uint64_t (formerly uint32_t). This avoids clear_vmcs_bit() to accidentally
clears the upper 32 bits of the requested VMCS field.
Other than that, this patch has no semantic change. Specifically this patch
is not meant to fix buggy narrowing operations, only to make these
operations explicit.
Tracked-On: #6776
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
Rename SOS_VM type to SERVICE_VM
rename UOS to User VM in XML description
rename uos_thread_pid to user_vm_thread_pid
rename devname_uos to devname_user_vm
rename uosid to user_vmid
rename UOS_ACK to USER_VM_ACK
rename SOS_VM_CONFIG_CPU_AFFINITY to SERVICE_VM_CONFIG_CPU_AFFINITY
rename SOS_COM to SERVICE_VM_COM
rename SOS_UART1_VALID_NUM" to SERVICE_VM_UART1_VALID_NUM
rename SOS_BOOTARGS_DIFF to SERVICE_VM_BOOTARGS_DIFF
rename uos to user_vm in launch script and xml
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Rename SOS_VM_NUM to SERVICE_VM_NUM.
rename SOS_SOCKET_PORT to SERVICE_VM_SOCKET_PORT.
rename PROCESS_RUN_IN_SOS to PROCESS_RUN_IN_SERVICE_VM.
rename PCI_DEV_TYPE_SOSEMUL to PCI_DEV_TYPE_SERVICE_VM_EMUL.
rename SHUTDOWN_REQ_FROM_SOS to SHUTDOWN_REQ_FROM_SERVICE_VM.
rename PROCESS_RUN_IN_SOS to PROCESS_RUN_IN_SERVICE_VM.
rename SHUTDOWN_REQ_FROM_UOS to SHUTDOWN_REQ_FROM_USER_VM.
rename UOS_SOCKET_PORT to USER_VM_SOCKET_PORT.
rename SOS_CONSOLE to SERVICE_VM_OS_CONSOLE.
rename SOS_LCS_SOCK to SERVICE_VM_LCS_SOCK.
rename SOS_VM_BOOTARGS to SERVICE_VM_OS_BOOTARGS.
rename SOS_ROOTFS to SERVICE_VM_ROOTFS.
rename SOS_IDLE to SERVICE_VM_IDLE.
rename SEVERITY_SOS to SEVERITY_SERVICE_VM.
rename SOS_VM_UUID to SERVICE_VM_UUID.
rename SOS_REQ to SERVICE_VM_REQ.
rename RTCT_NATIVE_FILE_PATH_IN_SOS to RTCT_NATIVE_FILE_PATH_IN_SERVICE_VM.
rename CBC_REQ_T_UOS_ACTIVE to CBC_REQ_T_USER_VM_ACTIVE.
rename CBC_REQ_T_UOS_INACTIVE to CBC_REQ_T_USER_VM_INACTIV.
rename uos_active to user_vm_active.
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Rename sos_vm to service_vm.
rename sos_vmid to service_vmid.
rename sos_vm_ptr to service_vm_ptr.
rename get_sos_vm to get_service_vm.
rename sos_vm_gpa to service_vm_gpa.
rename sos_vm_e820 to service_vm_e820.
rename sos_efi_info to service_vm_efi_info.
rename sos_vm_config to service_vm_config.
rename sos_vm_hpa2gpa to service_vm_hpa2gpa.
rename vdev_in_sos to vdev_in_service_vm.
rename create_sos_vm_e820 to create_service_vm_e820.
rename sos_high64_max_ram to service_vm_high64_max_ram.
rename prepare_sos_vm_memmap to prepare_service_vm_memmap.
rename post_uos_sworld_memory to post_user_vm_sworld_memory
rename hcall_sos_offline_cpu to hcall_service_vm_offline_cpu.
rename filter_mem_from_sos_e820 to filter_mem_from_service_vm_e820.
rename create_sos_vm_efi_mmap_desc to create_service_vm_efi_mmap_desc.
rename HC_SOS_OFFLINE_CPU to HC_SERVICE_VM_OFFLINE_CPU.
rename SOS to Service VM in comments message.
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Instead of "#include <x86/foo.h>", use "#include <asm/foo.h>".
In other words, we are adopting the same practice in Linux kernel.
Tracked-On: #5920
Signed-off-by: Liang Yi <yi.liang@intel.com>
Reviewed-by: Jason Chen CJ <jason.cj.chen@intel.com>
Requires explicit arch path name in the include directive.
The config scripts was also updated to reflect this change.
Tracked-On: #5825
Signed-off-by: Peter Fang <peter.fang@intel.com>
Reviewed-by: Jason Chen CJ <jason.cj.chen@intel.com>
This patch denies Service VM the access permission to device resources
owned by hypervisor.
HV may own these devices: (1) debug uart pci device for debug version
(2) type 1 pci device if have pre-launched VMs.
Current implementation exposes the mmio/pio resource of HV owned devices
to SOS, should remove them from SOS.
Tracked-On: #5615
Signed-off-by: Tao Yuhong <yuhong.tao@intel.com>
- Refactor pci_dev_c.py to insert devices information per VMs
- Add function to get unused vbdf form bus:dev.func 00:00.0 to 00:1F.7
Add pci devices variables to vm_configurations.c
- To pass the pci vuart information form tool, add pci_dev_num and
pci_devs initialization by tool
- Change CONFIG_SOS_VM in hypervisor/include/arch/x86/vm_config.h to
compromise vm_configurations.c
Tracked-On: #5426
Signed-off-by: Yang, Yu-chu <yu-chu.yang@intel.com>
According PCI Code and ID Assignment Specification Revision 1.11, a PCI device
whose Base Class is 06h and Sub-Class is 00h is a Host bridge.
Tracked-On: #4550
Signed-off-by: Li Fei1 <fei1.li@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
The init_one_dev_config is used to initialize a acrn_vm_pci_dev_config
SRIOV needs a explicit acrn_vm_pci_dev_config to create a VF vdev,so
refine it to return acrn_vm_pci_dev_config.
Tracked-On: #4433
Signed-off-by: Yuan Liu <yuan1.liu@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
Make the SRIOV-Capable device invisible from SOS if there is
no room for its all virtual functions.
v2: fix a issue that if a PF has been dropped, the subsequent PF
will be dropped too even there is room for its VFs.
Tracked-On: #4433
Signed-off-by: Yuan Liu <yuan1.liu@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
- update the function argument type to union
Declaring argument as pointer is not necessary since it
only does the comparison.
Tracked-On: #1842
Signed-off-by: Shiqing Gao <shiqing.gao@intel.com>
Add a field (vdev_ops) in struct acrn_vm_pci_dev_config to configure a PCI CFG
operation for an emulated PCI device. Use pci_pt_dev_ops for PCI_DEV_TYPE_PTDEV
by default if there's no such configure.
Tracked-On: #3475
Signed-off-by: Li, Fei1 <fei1.li@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
Add emulated PCI device configure for SOS to prepare for add support for customizing
special pci operations for each emulated PCI device.
Tracked-On: #3475
Signed-off-by: Li, Fei1 <fei1.li@intel.com>
Align SOS pci device configure with pre-launched VM and filter pre-launched VM's
PCI PT device from SOS pci device configure.
Tracked-On: #3475
Signed-off-by: Li, Fei1 <fei1.li@intel.com>