Doc: Update system power management doc
Signed-off-by: Yin Fengwei <fengwei.yin@intel.com>
This commit is contained in:
parent
3a4af4b096
commit
98fa9a81cd
|
@ -13,8 +13,8 @@ CPU P-state/C-state are controlled by the guest OS. The ACPI
|
|||
P/C-state driver relies on some P/C-state-related ACPI data in the guest
|
||||
ACPI table.
|
||||
|
||||
SOS could run ACPI driver with no problem because it can access native
|
||||
the ACPI table. For UOS though, we need to prepare the corresponding ACPI data
|
||||
Service VM could run ACPI driver with no problem because it can access native
|
||||
the ACPI table. For User VM though, we need to prepare the corresponding ACPI data
|
||||
for Device Model to build virtual ACPI table.
|
||||
|
||||
The Px/Cx data includes four
|
||||
|
@ -59,7 +59,7 @@ Virtual ACPI table build flow
|
|||
=============================
|
||||
|
||||
:numref:`vACPItable` shows how to build virtual ACPI table with
|
||||
Px/Cx data for UOS P/C-state management:
|
||||
Px/Cx data for User VM P/C-state management:
|
||||
|
||||
.. figure:: images/hld-pm-image28.png
|
||||
:align: center
|
||||
|
@ -68,16 +68,16 @@ Px/Cx data for UOS P/C-state management:
|
|||
System block for building vACPI table with Px/Cx data
|
||||
|
||||
Some ioctl APIs are defined for Device model to query Px/Cx data from
|
||||
SOS VHM. The Hypervisor needs to provide hypercall APIs to transit Px/Cx
|
||||
data from CPU state table to SOS VHM.
|
||||
Service VM VHM. The Hypervisor needs to provide hypercall APIs to transit
|
||||
Px/Cx data from CPU state table to Service VM VHM.
|
||||
|
||||
The build flow is:
|
||||
|
||||
1) Use offline tool (e.g. **iasl**) to parse the Px/Cx data and hard-code to
|
||||
CPU state table in Hypervisor. Hypervisor loads the data after
|
||||
system boot up.
|
||||
2) Before UOS launching, Device mode queries the Px/Cx data from SOS VHM
|
||||
via ioctl interface.
|
||||
2) Before User VM launching, Device mode queries the Px/Cx data from Service
|
||||
VM VHM via ioctl interface.
|
||||
3) VHM transmits the query request to Hypervisor by hypercall.
|
||||
4) Hypervisor returns the Px/Cx data.
|
||||
5) Device model builds the virtual ACPI table with these Px/Cx data
|
||||
|
@ -103,77 +103,91 @@ impact both power and performance.
|
|||
|
||||
S3/S5
|
||||
*****
|
||||
ACRN is designed to support the system level S3/S5 with following
|
||||
assumptions:
|
||||
|
||||
1) Guest has complete S3/S5 power state management.
|
||||
2) Guest follows the ACPI standard to implement S3/S5.
|
||||
3) Guest is responsible for saving its contents before entering S3/S5.
|
||||
4) Highest severity guest's power state is promoted to system power state.
|
||||
5) Guest has lifecycle manager running to handle power state transaction
|
||||
requirement and initialize guest power state transaction.
|
||||
6) S3 is only available on configurations which has no DM launched RTVM.
|
||||
7) S3 is only supported at platform level - not VM level.
|
||||
|
||||
ACRN has a common implementation for notification between lifecycle manager
|
||||
in different guest. Which is vUART based cross-vm notification. But user
|
||||
could customize it according to their hardware/software requirements.
|
||||
|
||||
:numref:`systempmdiag` shows the basic system level S3/S5 diagram
|
||||
|
||||
.. figure:: images/hld-pm-image62.png
|
||||
:align: center
|
||||
:name: systempmdiag
|
||||
|
||||
ACRN System S3/S5 diagram
|
||||
|
||||
ACRN assumes guest has complete S3/S5 power state management and follows
|
||||
the ACPI standard exactly. System S3/S5 needs to follow well-defined
|
||||
enter/exit paths and cooperate among different components.
|
||||
|
||||
System low power state enter process
|
||||
====================================
|
||||
|
||||
Each time, when OSPM of UOS starts power state transition, it will
|
||||
finally write the ACPI register per ACPI spec requirement.
|
||||
With help of ACRN I/O emulation framework, the UOS ACPI
|
||||
register writing will be dispatched to Device Model and Device Model
|
||||
will emulate the UOS power state (pause UOS VM for S3 and power off UOS
|
||||
VM for S5)
|
||||
Each time, when lifecycle manager of User VM starts power state transition,
|
||||
it will finally write the ACPI register per ACPI spec requirement. With
|
||||
help of ACRN I/O emulation framework, the User VM ACPI register writing
|
||||
will be dispatched to Device Model and Device Model will emulate the User VM
|
||||
power state (pause User VM for S3 and power off User VM for S5)
|
||||
|
||||
The VM Manager monitors all UOS. If all active UOSes are in required power
|
||||
state, VM Manager will notify OSPM of SOS to start SOS power state
|
||||
transition. OSPM of SOS follows a very similar process as UOS for power
|
||||
state transition. The difference is SOS ACPI register writing is trapped
|
||||
to ACRN HV. And ACRN HV will emulate SOS power state (pause SOS VM for
|
||||
S3 and no special action for S5)
|
||||
The VM Manager monitors all User VMs. If all active User VMs are in required
|
||||
power state, VM Manager will notify lifecyle manager of Service VM to start
|
||||
Service VM power state transition. lifecycle manager of Service VM follows
|
||||
a very similar process as User VM for power state transition. The difference
|
||||
is Service VM ACPI register writing is trapped to ACRN HV. And ACRN HV will
|
||||
emulate Service VM power state (pause Service VM for S3 and no special
|
||||
action for S5)
|
||||
|
||||
Once SOS low power state is done, ACRN HV will go through its own low
|
||||
Once Service VM low power state is done, ACRN HV will go through its own low
|
||||
power state enter path.
|
||||
|
||||
The whole system is finally put into low power state.
|
||||
|
||||
:numref:`pmworkflow` shows the flow of low power S5 enter process
|
||||
with typical ISD configuration(S3 follows very similar process)
|
||||
|
||||
.. figure:: images/hld-pm-image63.png
|
||||
:align: center
|
||||
:name: pmworkflow
|
||||
|
||||
ACRN system S5 enter workflow
|
||||
|
||||
For system power state entry:
|
||||
|
||||
1. Service VM received S5 request.
|
||||
2. Lifecycle manager in Service VM notify User VM1 and RTVM through
|
||||
vUART for S5 request.
|
||||
3. Guest lifecycle manager initliaze S5 action. And guest enter S5.
|
||||
4. RTOS cleanup rt task, send response of S5 request back to Service
|
||||
VM and RTVM enter S5.
|
||||
5. After get response from RTVM and all User VM are shutdown, Sevice VM
|
||||
enter S5.
|
||||
6. OSPM in ACRN hypervisor check all guest in S5 state and shutdown
|
||||
whole system.
|
||||
|
||||
System low power state exit process
|
||||
===================================
|
||||
|
||||
The low power state exit process is in reverse order. The ACRN
|
||||
hypervisor is woken up at first. It will go through its own low power
|
||||
state exit path. Then ACRN hypervisor will resume the SOS to let SOS go
|
||||
through SOS low power state exit path. After that, the DM is resumed and
|
||||
let UOS go through UOS low power state exit path. The system is resumed
|
||||
to running state after at least one UOS is resumed to running state.
|
||||
state exit path. Then ACRN hypervisor will resume the Service VM to let
|
||||
Service VM go through Service VM low power state exit path. After that,
|
||||
the DM is resumed and let User VM go through User VM low power state exit
|
||||
path. The system is resumed to running state after at least one User VM
|
||||
is resumed to running state.
|
||||
|
||||
:numref:`pmworkflow` shows the flow of low power S3 enter/exit process (S5 follows
|
||||
very similar process)
|
||||
|
||||
.. figure:: images/hld-pm-image62.png
|
||||
:align: center
|
||||
:name: pmworkflow
|
||||
|
||||
ACRN system power management workflow
|
||||
|
||||
For system power state entry:
|
||||
|
||||
1. UOS OSPM start UOS S3 entry
|
||||
2. The UOS S3 entering request is trapped ACPI PM Device of DM
|
||||
3. DM pauses UOS VM to emulate UOS S3 and notifies VM Manager that the UOS
|
||||
dedicated to it is in S3
|
||||
4. If all UOSes are in S3, VM Manager will notify OSPM of SOS
|
||||
5. SOS OSPM starts SOS S3 enter
|
||||
6. SOS S3 entering request is trapped to Sx Agency in ACRN HV
|
||||
7. ACRN HV pauses SOS VM to emulate SOS S3 and starts ACRN HV S3 entry.
|
||||
|
||||
For system power state exit:
|
||||
|
||||
1. When system is resumed from S3, native bootloader will jump to wake
|
||||
up vector of HV
|
||||
2. HV resumes S3 and jumps to wake up vector to emulate SOS resume from S3
|
||||
3. OSPM of SOS is running
|
||||
4. OSPM of SOS notifies VM Manager that it's ready to wake up UOS
|
||||
5. VM Manager will notify DM to resume the UOS
|
||||
6. DM resets the UOS VM to emulate UOS resume from S3
|
||||
|
||||
According to ACPI standard, S3 is mapped to suspend to RAM and S5 is
|
||||
mapped to shutdown. So the S5 process is a little different:
|
||||
|
||||
- UOS enters S3 -> UOS powers off
|
||||
- System enters S3 -> System powers off
|
||||
- System resumes From S3 -> System fresh start
|
||||
- UOS resumes from S3 -> UOS fresh startup
|
||||
- User VM enters S5 -> User VM powers off
|
||||
- System enters S5 -> System powers off
|
||||
- System resumes From S5 -> System fresh start
|
||||
- User VM resumes from S5 -> User VM fresh startup
|
||||
|
|