acrn-config: enable more VMs in TGL xml
Add more VMs in xml. Enable vuart0 for VM1. Tracked-On: #5013 Signed-off-by: Conghui Chen <conghui.chen@intel.com>
This commit is contained in:
parent
213cd4e2b2
commit
6722132233
|
@ -52,103 +52,254 @@
|
|||
</MISC_CFG>
|
||||
</hv>
|
||||
|
||||
<vm id="0">
|
||||
<vm_type desc="Specify the VM type" readonly="true">SOS_VM</vm_type>
|
||||
<name desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">ACRN SOS VM</name>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag />
|
||||
</guest_flags>
|
||||
<clos configurable="0" desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<memory>
|
||||
<start_hpa configurable="0" desc="The start physical address in host for the VM">0</start_hpa>
|
||||
<size configurable="0" desc="The memory size in Bytes for the VM">0x20000000</size>
|
||||
</memory>
|
||||
<os_config>
|
||||
<name desc="Specify the OS name of VM, currently it is not referenced by hypervisor code.">ACRN Service OS</name>
|
||||
<kern_type desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">KERNEL_BZIMAGE</kern_type>
|
||||
<kern_mod desc="The tag for kernel image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline.">Linux_bzImage</kern_mod>
|
||||
<ramdisk_mod desc="The tag for ramdisk image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline."></ramdisk_mod>
|
||||
<bootargs configurable="0" desc="Specify kernel boot arguments">SOS_VM_BOOTARGS</bootargs>
|
||||
</os_config>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address." readonly="true">SOS_COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">SOS_COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">SOS_COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">2</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
<pci_devs configurable="0" desc="pci devices list">
|
||||
<pci_dev desc="pci device"></pci_dev>
|
||||
</pci_devs>
|
||||
<board_private>
|
||||
<rootfs desc="rootfs for Linux kernel">/dev/nvme0n1p3</rootfs>
|
||||
<bootargs desc="Specify kernel boot arguments"> rw rootwait console=ttyS0 consoleblank=0 no_timer_check quiet loglevel=3 i915.nuclear_pageflip=1
|
||||
</bootargs>
|
||||
</board_private>
|
||||
</vm>
|
||||
<vm id="1">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag />
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="vCPU affinity map. Each vCPU will pin to the selected pCPU ID. Please make sure each vCPU pin to different pCPU.">
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="2">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_RT_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>2</pcpu_id>
|
||||
<pcpu_id>3</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM2_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="0">
|
||||
<vm_type desc="Specify the VM type" readonly="true">SOS_VM</vm_type>
|
||||
<name desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">ACRN SOS VM</name>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag />
|
||||
</guest_flags>
|
||||
<clos configurable="0" desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<memory>
|
||||
<start_hpa configurable="0" desc="The start physical address in host for the VM">0</start_hpa>
|
||||
<size configurable="0" desc="The memory size in Bytes for the VM">0x20000000</size>
|
||||
</memory>
|
||||
<os_config>
|
||||
<name desc="Specify the OS name of VM, currently it is not referenced by hypervisor code.">ACRN Service OS</name>
|
||||
<kern_type desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">KERNEL_BZIMAGE</kern_type>
|
||||
<kern_mod desc="The tag for kernel image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline.">Linux_bzImage</kern_mod>
|
||||
<ramdisk_mod desc="The tag for ramdisk image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline."></ramdisk_mod>
|
||||
<bootargs configurable="0" desc="Specify kernel boot arguments">SOS_VM_BOOTARGS</bootargs>
|
||||
</os_config>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address." readonly="true">SOS_COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">SOS_COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">SOS_COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">2</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
<pci_devs configurable="0" desc="pci devices list">
|
||||
<pci_dev desc="pci device"></pci_dev>
|
||||
</pci_devs>
|
||||
<board_private>
|
||||
<rootfs desc="rootfs for Linux kernel">/dev/nvme0n1p3</rootfs>
|
||||
<bootargs desc="Specify kernel boot arguments"> rw rootwait console=ttyS0 consoleblank=0 no_timer_check quiet loglevel=3 i915.nuclear_pageflip=1
|
||||
</bootargs>
|
||||
</board_private>
|
||||
</vm>
|
||||
<vm id="1">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag />
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="vCPU affinity map. Each vCPU will pin to the selected pCPU ID. Please make sure each vCPU pin to different pCPU.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="2">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_RT_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>2</pcpu_id>
|
||||
<pcpu_id>3</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM2_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
|
||||
<vm id="3">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="4">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="5">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="6">
|
||||
<vm_type desc="Specify the VM type" readonly="true">POST_STD_VM</vm_type>
|
||||
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
|
||||
<guest_flag>0</guest_flag>
|
||||
</guest_flags>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
<vm id="7" configurable="1" desc="specific for Kata">
|
||||
<vm_type readonly="true" desc="Specify the VM type">KATA_VM</vm_type>
|
||||
<cpu_affinity desc="List of pCPU: the guest VM is allowed to create vCPU from all or a subset of this list.">
|
||||
<pcpu_id>0</pcpu_id>
|
||||
<pcpu_id>1</pcpu_id>
|
||||
</cpu_affinity>
|
||||
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
<vcpu_clos>0</vcpu_clos>
|
||||
</clos>
|
||||
<epc_section configurable="0" desc="epc section">
|
||||
<base desc="SGX EPC section base, must be page aligned">0</base>
|
||||
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
|
||||
</epc_section>
|
||||
<vuart id="0">
|
||||
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
|
||||
<base configurable="0" desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
|
||||
</vuart>
|
||||
<vuart id="1">
|
||||
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
|
||||
<base configurable="0" desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
|
||||
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
|
||||
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
|
||||
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">0</target_uart_id>
|
||||
</vuart>
|
||||
</vm>
|
||||
</acrn-config>
|
||||
|
|
Loading…
Reference in New Issue